1040-P: Feasibility and Performance of Continuous Glucose Monitoring (CGM) to Guide Computerized Insulin Infusion Therapy in Cardiovascular Intensive Care Unit (CV-ICU)

We evaluated the utility of real-time CGM for titrating intravenous (IV) insulin via a validated institutional computerized insulin infusion (CII) algorithm in the CV-ICU. We used a hybrid approach of combining CGM with periodic point-of-care blood glucose (POC-BG) tests to validate the continued ac...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diabetes (New York, N.Y.) N.Y.), 2023-06, Vol.72 (Supplement_1), p.1
Hauptverfasser: ANG, LYNN, AKANBI, FOLAKE, SCHROEDER, LEE F., KUEI LIN, YU, DEGEORGE, CHRISTINA A., ARNOLD, PATRICK, KNOTTS, SHARON, DUBOIS, ELIZABETH, DESBROUGH, NICOLE, QU, YUNYAN, FREEMAN, REGI, ESFANDIARI, NAZANENE H., BUSUI, RODICA, GIANCHANDANI, ROMA
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We evaluated the utility of real-time CGM for titrating intravenous (IV) insulin via a validated institutional computerized insulin infusion (CII) algorithm in the CV-ICU. We used a hybrid approach of combining CGM with periodic point-of-care blood glucose (POC-BG) tests to validate the continued accuracy of CGM. We also surveyed nurses on this care change. Dexcom G6 CGMs were applied to 61 post-surgical patients with hyperglycemia (34% with diabetes) receiving IV insulin. CGM values were validated with POC-BG every(Q) 1-2 h per the CII protocol. Once validated (i.e., within 20% of POC-BG values if BG ≥100 mg/dL or within 20 mg/dL if BG
ISSN:0012-1797
1939-327X
DOI:10.2337/db23-1040-P