A Boiler Feed Pump Speed Control to Reduce Its Own Power Consumption According to Pump Affinity Law

The change in water flow required at the BFP pump at the Barru Power Plant is only regulated by a valve located on the pressure side, causing excess power consumption and its own power consumption. One effort to save energy usage is to make frequency adjustments that refer to the right pressure and...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Earth and environmental science 2023-07, Vol.1209 (1), p.12029
Hauptverfasser: Indrawan, Andi Wawan, Purwito, Ashar, AR, Sultan, Ahmad Rizal, Imanulloh, Setio
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The change in water flow required at the BFP pump at the Barru Power Plant is only regulated by a valve located on the pressure side, causing excess power consumption and its own power consumption. One effort to save energy usage is to make frequency adjustments that refer to the right pressure and water flow. To determine the effect of frequency adjustments on the expected pump pressure, a simulation of frequency inverter modeling is performed using the SPWM switching method based on the pump affinity law using Matlab application software. The simulation results obtained that by adjusting the frequency range of the inverter from 45.5 Hz to 50 Hz and keeping the pump pressure above the minimum limit of 13.2 MPa, the operating power savings of the BFP motor are obtained from 46 kW to 378 kW.
ISSN:1755-1307
1755-1315
DOI:10.1088/1755-1315/1209/1/012029