Superconducting Undulator with a Period of 15.6 mm and Magnetic Field of 1.2 T
A superconducting undulator created at the Budker Institute of Nuclear Physics with a period of 15.6 mm and a field of 1.2 T is tested in own undulator cryostat based on indirect cooling with zero helium consumption. The main characteristics and design features of the magnetic and cryogenic systems...
Gespeichert in:
Veröffentlicht in: | Bulletin of the Russian Academy of Sciences. Physics 2023-05, Vol.87 (5), p.552-558 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A superconducting undulator created at the Budker Institute of Nuclear Physics with a period of 15.6 mm and a field of 1.2 T is tested in own undulator cryostat based on indirect cooling with zero helium consumption. The main characteristics and design features of the magnetic and cryogenic systems of this insertion device are presented. Results from measuring the magnetic field are presented. Features of the operation of a cryogenic system in different modes are discussed. |
---|---|
ISSN: | 1062-8738 1934-9432 |
DOI: | 10.3103/S1062873822701830 |