Determination of isocarbophos by cathodically sweeping oscilliopolarography

Determination of isocarbophos by cathodically sweeping oscilliopolarography is described. In a 1.0×10−5 mol/L sodium dodecylbenzene sulfonate (SDS)+0.1 mol/L HAC-NaAC (pH=4.0) buffer medium, isocarbophos and its alkaline hydrolysate exhibited sensitive second derivative wave at −0.50 V and −0.48 V r...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Wuhan University journal of natural sciences 1999-09, Vol.4 (3), p.335-340
Hauptverfasser: Wu-ming, Zhang, Nan, Li, Jun-hua, Huang, Cheng, Fang, Xing-yao, Zhou
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Determination of isocarbophos by cathodically sweeping oscilliopolarography is described. In a 1.0×10−5 mol/L sodium dodecylbenzene sulfonate (SDS)+0.1 mol/L HAC-NaAC (pH=4.0) buffer medium, isocarbophos and its alkaline hydrolysate exhibited sensitive second derivative wave at −0.50 V and −0.48 V respectively. The peak current was linearly proportional to the concentration of isocarbophos in the range of 5.40×10−6−1.05×10−4 mol/L by detecting isocarbophos directly. The detection limit was 3.60×10−6 mol/L with the relative standard derivation (RSD) of 7.3%. By employing an alkaline hydrolysis, the peak current was linearly proportional to the concentration of isocarbophos in the range from 7.70×10−7 mol/L to 1.24×10−4 mol/L, and the detection limit was 5.80×10−7 mol/L with RSD of 3.1%. The hydrolysis procedure and the electrode reaction were studied by voltammetry.
ISSN:1007-1202
1993-4998