Investigation of novel preclinical Total Body PET designed with J-PET technology: A simulation study

The growing interest in human-grade Total Body PET systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animalbased research became a necessary step for testing and protocol preparatio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on radiation and plasma medical sciences 2023-02, Vol.7 (2), p.1-1
Hauptverfasser: Dadgar, M., Parzych, S., Ardebili, F. Tayefi, Baran, J., Chug, N., Curceanu, C., Czerwinski, E., Dulski, K., Eliyan, K., Gajos, A., Hiesmayr, B.C., Kacprzak, K., Kaplon, L., Klimaszewski, K., Konieczka, P., Korcyl, G., Kozik, T., Krzemien, W., Kumar, D., Niedzwiecki, S., Panek, D., del Rio, E. Perez, Raczynski, L., Sharma, S., Shivani, Shopa, R.Y., Skurzok, M., Ardebili, K. Tayefi, Vandenberghe, S., Wislicki, W., Stepien, E.L., Moskal, P.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The growing interest in human-grade Total Body PET systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animalbased research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost effective small animal Total Body PET scanners (for mouse and rat studies) have been investigated in order to inspect their feasibility for preclinical research. They were designed with the novel technology explored by the Jagiellonian PET Collaboration (J-PET). Two main PET characteristics: sensitivity and spatial resolution were mainly inspected to evaluate their performance. Moreover, the impact of the scintillator dimension and time-offlight on the latter parameter were examined in order to design the most efficient tomographs. The presented results show that for mouse TB J-PET the achievable system sensitivity is equal to 2.35% and volumetric spatial resolution to 9.46 ± 0.54 mm3, while for rat TB J-PET they are equal to 2.6% and 14.11 ± 0.80 mm3, respectively. Furthermore, it was shown that the designed tomographs are almost parallax-free systems, hence they resolve the problem of the acceptance criterion trade-off between enhancing spatial resolution and reducing sensitivity.
ISSN:2469-7311
2469-7303
DOI:10.1109/TRPMS.2022.3211780