Surface and Subsurface Defects Formed in a Cold-Rolled Electrical Steel

The causes for the formation of defects of different characteristics on an electrical-grade cold-rolled steel strip surface are presented. Inspection of material taken from coils that presented failure was conducted using field emission scanning electron microscopy (FEGSEM), energy-dispersive x-ray...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of failure analysis and prevention 2023-02, Vol.23 (1), p.298-305
Hauptverfasser: Garza-Montes-de-Oca, Nelson F., Pineda-Arriaga, Karen Y., Gaona-Martínez, Mauro J., Ramírez-Ramírez, Javier H., Pérez-González, Francisco A., Colás, Rafael
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The causes for the formation of defects of different characteristics on an electrical-grade cold-rolled steel strip surface are presented. Inspection of material taken from coils that presented failure was conducted using field emission scanning electron microscopy (FEGSEM), energy-dispersive x-ray analyses (EDX), and confocal microscopy (CM). The surface and cross section analyses of selected specimens suggested that the formation of holes and scale-like defects during cold rolling could be related to a considerable number of non-metallic inclusions dispersed within the metallic matrix, the presence of both small MnS particles and silicon-rich oxides in the alloy.
ISSN:1547-7029
1728-5674
1864-1245
DOI:10.1007/s11668-022-01576-6