Risk factors associated with fixation‐related complications in microsurgical free flap reconstruction of the mandible
Background Hardware complications (loosening of screws, infection, or exposure of the plate) in mandibular reconstruction with vascularized osseous free flaps impose significant morbidity, and frequently require revision surgery. Purpose of this study was to identify possible contributing factors fo...
Gespeichert in:
Veröffentlicht in: | Microsurgery 2023-01, Vol.43 (1), p.27-38 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Hardware complications (loosening of screws, infection, or exposure of the plate) in mandibular reconstruction with vascularized osseous free flaps impose significant morbidity, and frequently require revision surgery. Purpose of this study was to identify possible contributing factors for hardware complications.
Methods
This is a retrospective cohort study involving case series of patients who underwent microvascular mandible reconstructions between 2000 and 2020. Patient demographics, pathological, clinical, and treatment‐related factors were analyzed in univariate and multivariate analyses.
Results
Ninety‐one patients were enrolled, encompassing 63 reconstructions with fibular free flaps, 26 reconstructions with scapular, and 2 reconstructions with iliac flaps. Rate of hardware complications and plate exposure was 14.3% and 7.7%, respectively, with a median follow‐up time for extrusion of 29 months. In univariate analysis, preoperative radiotherapy (odds ratio [OR] = 6.57, p = .01), and secondary mandible reconstruction (OR = 4.3, p = .04) were significant predictors of hardware complications, and plate exposure was most frequently found in secondary reconstruction (37.5%, OR = 11.8, p = .04). Hypertension was the most commonly found comorbidity (24%), and it trended toward significance regarding plate exposure (p = .05). Only secondary mandible reconstruction was associated with osteosynthesis complications (OR = 12.53, p = .01) and plate exposure (OR = 23.86, p = .005) on multivariate analysis, while preoperative radiation therapy did not retain its relevance on plate exposure.
Conclusion
Secondary mandible reconstructions with vascularized osseous free flaps have a higher risk of osteosynthesis complications than primary reconstructions. |
---|---|