Resistive High-Voltage Probe with Frequency Compensation by Planar Compensation Electrode Integrated in Printed Circuit Board Design

Resistive voltage dividers tend to have a highly non-linear transfer function as parasitic and stray capacitances exert an increasing influence with increasing frequency. The non-linear transfer function depends on the topology and resistors used and consists of a low-pass filter with an additional...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electronics (Basel) 2022-11, Vol.11 (21), p.3446
Hauptverfasser: Winkelholz, Jonas, Hitzemann, Moritz, Nitschke, Alexander, Zygmanowski, Anne, Zimmermann, Stefan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Resistive voltage dividers tend to have a highly non-linear transfer function as parasitic and stray capacitances exert an increasing influence with increasing frequency. The non-linear transfer function depends on the topology and resistors used and consists of a low-pass filter with an additional high-pass component in the GHz range. Due to the non-linear transfer function the measured signal differs from the original input signal. Here, we present an improved resistive voltage divider with additional compensation capacities to extend the linear bandwidth. With this new concept, the linear bandwidth is improved from 115 kHz to 88 MHz, while maintaining a DC input impedance of 10 MΩ. For high-voltage insulation and easy manufacturing, surface mounted resistors on a printed circuit board with a compensation electrode on the adjacent side are used. The performance of this resistive voltage divider is demonstrated by measuring a series of high-voltage pulses with an amplitude of 2.5 kVpeak-peak. The measured pulse rise time is about 16 ns, corresponding to an average slew-rate of 150 V/ns. Finally, the developed resistive voltage divider is successfully used to measure fast high-voltage transients required for advanced ion mobility spectrometers with integrated collision induced fragmentation.
ISSN:2079-9292
2079-9292
DOI:10.3390/electronics11213446