Punching Shear Resistance of Corroded Slab–Column Connections Subjected to Eccentric Load

AbstractDue to the use of deicing salt, marine and offshore environments may cause rebar corrosion in RC flat-slab floor systems. This increases the possibility of punching shear failure of slab–column connections. However, few research results are available for RC slab–column connections with corro...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of structural engineering (New York, N.Y.) N.Y.), 2023-01, Vol.149 (1)
Hauptverfasser: Weng, Yun-Hao, Fu, Feng, Qian, Kai
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 1
container_start_page
container_title Journal of structural engineering (New York, N.Y.)
container_volume 149
creator Weng, Yun-Hao
Fu, Feng
Qian, Kai
description AbstractDue to the use of deicing salt, marine and offshore environments may cause rebar corrosion in RC flat-slab floor systems. This increases the possibility of punching shear failure of slab–column connections. However, few research results are available for RC slab–column connections with corroded rebar under eccentric load, which is very common in realistic loading conditions. To fill this gap, 15 full-scale RC flat slab–column connections were fabricated and tested to investigate the performance of corroded slab–column connections under eccentric load. The design variables included reinforcement ratio, loading eccentricity, and degree of rebar corrosion. There were two stages of the experimental process, including (1) accelerated rebar corrosion tests; and (2) quasi-static tests. It was found from the test results that, in general, rebar corrosion had detrimental effects on the punching shear strength and stiffness of the connections. In addition, corrosion of reinforcement may change the failure mode of slab–column connections. However, it was unexpected that the energy-dissipating capacity and deformation capacity of slab–column connections with high reinforcement ratio and small loading eccentricity increased with increasing corrosion degree.
doi_str_mv 10.1061/(ASCE)ST.1943-541X.0003504
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2731699918</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2731699918</sourcerecordid><originalsourceid>FETCH-LOGICAL-a318t-d04ed46516c0dbe6301680d82335e47aab3bc55828ccf8a1ed62fb5cfbc36aa03</originalsourceid><addsrcrecordid>eNp1kMtKAzEUhoMoWKvvEHSji6nJ5NKMuzLUCxQUp4LgImSSjJ3SJjWZWbjzHXxDn8QZWnXl6hwO3_8f-AA4xWiEEceX55Min14U8xHOKEkYxc8jhBBhiO6Bwe9tHwzQmJAko5QdgqMYlx00ZlgMwMtD6_Sidq-wWFgV4KONdWyU0xb6CuY-BG-sgcVKlV8fn7lftWvXnZ2zuqm9i7Boy2W3d0zj4VRr65pQazjzyhyDg0qtoj3ZzSF4up7O89tkdn9zl09miSJYNIlB1BrKGeYamdJygjAXyIiUEGbpWKmSlJoxkQqtK6GwNTytSqarUhOuFCJDcLbt3QT_1trYyKVvg-teynRMMM-yDIuOutpSOvgYg63kJtRrFd4lRrKXKWUvUxZz2YuTvTi5k9mF-TasorZ_9T_J_4PfgxZ66Q</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2731699918</pqid></control><display><type>article</type><title>Punching Shear Resistance of Corroded Slab–Column Connections Subjected to Eccentric Load</title><source>American Society of Civil Engineers:NESLI2:Journals:2014</source><creator>Weng, Yun-Hao ; Fu, Feng ; Qian, Kai</creator><creatorcontrib>Weng, Yun-Hao ; Fu, Feng ; Qian, Kai</creatorcontrib><description>AbstractDue to the use of deicing salt, marine and offshore environments may cause rebar corrosion in RC flat-slab floor systems. This increases the possibility of punching shear failure of slab–column connections. However, few research results are available for RC slab–column connections with corroded rebar under eccentric load, which is very common in realistic loading conditions. To fill this gap, 15 full-scale RC flat slab–column connections were fabricated and tested to investigate the performance of corroded slab–column connections under eccentric load. The design variables included reinforcement ratio, loading eccentricity, and degree of rebar corrosion. There were two stages of the experimental process, including (1) accelerated rebar corrosion tests; and (2) quasi-static tests. It was found from the test results that, in general, rebar corrosion had detrimental effects on the punching shear strength and stiffness of the connections. In addition, corrosion of reinforcement may change the failure mode of slab–column connections. However, it was unexpected that the energy-dissipating capacity and deformation capacity of slab–column connections with high reinforcement ratio and small loading eccentricity increased with increasing corrosion degree.</description><identifier>ISSN: 0733-9445</identifier><identifier>EISSN: 1943-541X</identifier><identifier>DOI: 10.1061/(ASCE)ST.1943-541X.0003504</identifier><language>eng</language><publisher>New York: American Society of Civil Engineers</publisher><subject>Accelerated tests ; Corrosion effects ; Corrosion resistance ; Corrosion tests ; Deicing salt ; Eccentric loads ; Eccentricity ; Failure modes ; Punching shear ; Rebar ; Reinforcement ; Shear strength ; Static tests ; Stiffness ; Structural engineering ; Technical Papers</subject><ispartof>Journal of structural engineering (New York, N.Y.), 2023-01, Vol.149 (1)</ispartof><rights>2022 American Society of Civil Engineers</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a318t-d04ed46516c0dbe6301680d82335e47aab3bc55828ccf8a1ed62fb5cfbc36aa03</citedby><cites>FETCH-LOGICAL-a318t-d04ed46516c0dbe6301680d82335e47aab3bc55828ccf8a1ed62fb5cfbc36aa03</cites><orcidid>0000-0002-9176-8159 ; 0000-0003-3851-2290 ; 0000-0002-8905-4384</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttp://ascelibrary.org/doi/pdf/10.1061/(ASCE)ST.1943-541X.0003504$$EPDF$$P50$$Gasce$$H</linktopdf><linktohtml>$$Uhttp://ascelibrary.org/doi/abs/10.1061/(ASCE)ST.1943-541X.0003504$$EHTML$$P50$$Gasce$$H</linktohtml><link.rule.ids>314,780,784,27924,27925,76193,76201</link.rule.ids></links><search><creatorcontrib>Weng, Yun-Hao</creatorcontrib><creatorcontrib>Fu, Feng</creatorcontrib><creatorcontrib>Qian, Kai</creatorcontrib><title>Punching Shear Resistance of Corroded Slab–Column Connections Subjected to Eccentric Load</title><title>Journal of structural engineering (New York, N.Y.)</title><description>AbstractDue to the use of deicing salt, marine and offshore environments may cause rebar corrosion in RC flat-slab floor systems. This increases the possibility of punching shear failure of slab–column connections. However, few research results are available for RC slab–column connections with corroded rebar under eccentric load, which is very common in realistic loading conditions. To fill this gap, 15 full-scale RC flat slab–column connections were fabricated and tested to investigate the performance of corroded slab–column connections under eccentric load. The design variables included reinforcement ratio, loading eccentricity, and degree of rebar corrosion. There were two stages of the experimental process, including (1) accelerated rebar corrosion tests; and (2) quasi-static tests. It was found from the test results that, in general, rebar corrosion had detrimental effects on the punching shear strength and stiffness of the connections. In addition, corrosion of reinforcement may change the failure mode of slab–column connections. However, it was unexpected that the energy-dissipating capacity and deformation capacity of slab–column connections with high reinforcement ratio and small loading eccentricity increased with increasing corrosion degree.</description><subject>Accelerated tests</subject><subject>Corrosion effects</subject><subject>Corrosion resistance</subject><subject>Corrosion tests</subject><subject>Deicing salt</subject><subject>Eccentric loads</subject><subject>Eccentricity</subject><subject>Failure modes</subject><subject>Punching shear</subject><subject>Rebar</subject><subject>Reinforcement</subject><subject>Shear strength</subject><subject>Static tests</subject><subject>Stiffness</subject><subject>Structural engineering</subject><subject>Technical Papers</subject><issn>0733-9445</issn><issn>1943-541X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp1kMtKAzEUhoMoWKvvEHSji6nJ5NKMuzLUCxQUp4LgImSSjJ3SJjWZWbjzHXxDn8QZWnXl6hwO3_8f-AA4xWiEEceX55Min14U8xHOKEkYxc8jhBBhiO6Bwe9tHwzQmJAko5QdgqMYlx00ZlgMwMtD6_Sidq-wWFgV4KONdWyU0xb6CuY-BG-sgcVKlV8fn7lftWvXnZ2zuqm9i7Boy2W3d0zj4VRr65pQazjzyhyDg0qtoj3ZzSF4up7O89tkdn9zl09miSJYNIlB1BrKGeYamdJygjAXyIiUEGbpWKmSlJoxkQqtK6GwNTytSqarUhOuFCJDcLbt3QT_1trYyKVvg-teynRMMM-yDIuOutpSOvgYg63kJtRrFd4lRrKXKWUvUxZz2YuTvTi5k9mF-TasorZ_9T_J_4PfgxZ66Q</recordid><startdate>20230101</startdate><enddate>20230101</enddate><creator>Weng, Yun-Hao</creator><creator>Fu, Feng</creator><creator>Qian, Kai</creator><general>American Society of Civil Engineers</general><scope>AAYXX</scope><scope>CITATION</scope><scope>8FD</scope><scope>FR3</scope><scope>KR7</scope><orcidid>https://orcid.org/0000-0002-9176-8159</orcidid><orcidid>https://orcid.org/0000-0003-3851-2290</orcidid><orcidid>https://orcid.org/0000-0002-8905-4384</orcidid></search><sort><creationdate>20230101</creationdate><title>Punching Shear Resistance of Corroded Slab–Column Connections Subjected to Eccentric Load</title><author>Weng, Yun-Hao ; Fu, Feng ; Qian, Kai</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a318t-d04ed46516c0dbe6301680d82335e47aab3bc55828ccf8a1ed62fb5cfbc36aa03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Accelerated tests</topic><topic>Corrosion effects</topic><topic>Corrosion resistance</topic><topic>Corrosion tests</topic><topic>Deicing salt</topic><topic>Eccentric loads</topic><topic>Eccentricity</topic><topic>Failure modes</topic><topic>Punching shear</topic><topic>Rebar</topic><topic>Reinforcement</topic><topic>Shear strength</topic><topic>Static tests</topic><topic>Stiffness</topic><topic>Structural engineering</topic><topic>Technical Papers</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Weng, Yun-Hao</creatorcontrib><creatorcontrib>Fu, Feng</creatorcontrib><creatorcontrib>Qian, Kai</creatorcontrib><collection>CrossRef</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Civil Engineering Abstracts</collection><jtitle>Journal of structural engineering (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Weng, Yun-Hao</au><au>Fu, Feng</au><au>Qian, Kai</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Punching Shear Resistance of Corroded Slab–Column Connections Subjected to Eccentric Load</atitle><jtitle>Journal of structural engineering (New York, N.Y.)</jtitle><date>2023-01-01</date><risdate>2023</risdate><volume>149</volume><issue>1</issue><issn>0733-9445</issn><eissn>1943-541X</eissn><abstract>AbstractDue to the use of deicing salt, marine and offshore environments may cause rebar corrosion in RC flat-slab floor systems. This increases the possibility of punching shear failure of slab–column connections. However, few research results are available for RC slab–column connections with corroded rebar under eccentric load, which is very common in realistic loading conditions. To fill this gap, 15 full-scale RC flat slab–column connections were fabricated and tested to investigate the performance of corroded slab–column connections under eccentric load. The design variables included reinforcement ratio, loading eccentricity, and degree of rebar corrosion. There were two stages of the experimental process, including (1) accelerated rebar corrosion tests; and (2) quasi-static tests. It was found from the test results that, in general, rebar corrosion had detrimental effects on the punching shear strength and stiffness of the connections. In addition, corrosion of reinforcement may change the failure mode of slab–column connections. However, it was unexpected that the energy-dissipating capacity and deformation capacity of slab–column connections with high reinforcement ratio and small loading eccentricity increased with increasing corrosion degree.</abstract><cop>New York</cop><pub>American Society of Civil Engineers</pub><doi>10.1061/(ASCE)ST.1943-541X.0003504</doi><orcidid>https://orcid.org/0000-0002-9176-8159</orcidid><orcidid>https://orcid.org/0000-0003-3851-2290</orcidid><orcidid>https://orcid.org/0000-0002-8905-4384</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0733-9445
ispartof Journal of structural engineering (New York, N.Y.), 2023-01, Vol.149 (1)
issn 0733-9445
1943-541X
language eng
recordid cdi_proquest_journals_2731699918
source American Society of Civil Engineers:NESLI2:Journals:2014
subjects Accelerated tests
Corrosion effects
Corrosion resistance
Corrosion tests
Deicing salt
Eccentric loads
Eccentricity
Failure modes
Punching shear
Rebar
Reinforcement
Shear strength
Static tests
Stiffness
Structural engineering
Technical Papers
title Punching Shear Resistance of Corroded Slab–Column Connections Subjected to Eccentric Load
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T16%3A42%3A51IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Punching%20Shear%20Resistance%20of%20Corroded%20Slab%E2%80%93Column%20Connections%20Subjected%20to%20Eccentric%20Load&rft.jtitle=Journal%20of%20structural%20engineering%20(New%20York,%20N.Y.)&rft.au=Weng,%20Yun-Hao&rft.date=2023-01-01&rft.volume=149&rft.issue=1&rft.issn=0733-9445&rft.eissn=1943-541X&rft_id=info:doi/10.1061/(ASCE)ST.1943-541X.0003504&rft_dat=%3Cproquest_cross%3E2731699918%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2731699918&rft_id=info:pmid/&rfr_iscdi=true