The Optimization of a First-Stage Liquid-Sealing Impeller Structure for a Turbopump Based on Response Surface Methodology

This study investigated the sealing performance of the multistage liquid-sealing impellers of a turbopump. To achieve this purpose, the influence of each structural parameter in the impeller on the pressurization coefficient φ2 and the leakage flow rate Q was analyzed based on response surface metho...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Processes 2022-10, Vol.10 (10), p.1999
Hauptverfasser: Liu, Qiong, Zhuang, Suguo, Bao, Haifeng, He, Zhoufeng, Wang, Kai, Liu, Houlin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study investigated the sealing performance of the multistage liquid-sealing impellers of a turbopump. To achieve this purpose, the influence of each structural parameter in the impeller on the pressurization coefficient φ2 and the leakage flow rate Q was analyzed based on response surface methodology, taking the maximum pressurization coefficient φ2 and the minimum leakage flow rate Q as the optimization objectives. We obtained satisfactory ranges for parameters φ2 and Q. A set of parameter combinations was selected as the optimization scheme using the Box–Behnken method for the optimal solution design. The numerical simulation results show that to keep φ2 and Q in the better range, the value ranges of groove width b, groove depth h and groove number z should be (12.8–14 mm), (4.5–5.6 mm) and (23.5–28), respectively. Compared with the original model, the optimized version has an average increase of about 2.5% in pressurization coefficient φ2 at each rotation speed, an average of about 8.2% reduction in the leakage flow rate Q in the leakage state and an average increase in the reverse flow rate Q by about 6.7% in the negative pressure sealing state, indicating better sealing. By comparing pressure data at the experimental monitoring points, the proposed method was verified to have a high degree of confidence.
ISSN:2227-9717
2227-9717
DOI:10.3390/pr10101999