iDREAM: industrial Detector of REactor Antineutrinos for Monitoring at Kalinin nuclear power plant
The paper is devoted to the description of the iDREAM detector and its systems. iDREAM is a prototype detector designed to demonstrate the feasibility of antineutrino detectors for remote reactor monitoring and safeguard purposes. Antineutrinos are detected with a 1 ton liquid scintillator via inver...
Gespeichert in:
Veröffentlicht in: | Journal of instrumentation 2022-09, Vol.17 (9), p.P09001 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The paper is devoted to the description of the iDREAM
detector and its systems. iDREAM is a prototype detector designed to
demonstrate the feasibility of antineutrino detectors for remote
reactor monitoring and safeguard purposes. Antineutrinos are
detected with a 1 ton liquid scintillator via inverse beta decay on
protons. In order to suppress cosmic muons, gamma and neutron
background, the detector is housed in a dedicated shielding. The
detector is installed at the Kalinin nuclear power plant (Russia),
20 m from the 3 GW
th
reactor core. |
---|---|
ISSN: | 1748-0221 1748-0221 |
DOI: | 10.1088/1748-0221/17/09/P09001 |