Aerobic and anaerobic performance of lower- and upper-body in Brazilian jiu-jitsu athletes
To investigate the aerobic and anaerobic performance of lower- and upper-body of Brazilian jiu-jitsu athletes. Twelve male Brazilian jiu-jitsu athletes (26.3±6.6-years-old, 80.8±15.7kg) were assessed for lower- and upper-body aerobic and anaerobic fitness, body composition, squat jump, countermoveme...
Gespeichert in:
Veröffentlicht in: | Science & sports 2022-04, Vol.37 (2), p.145.e1-145.e8 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To investigate the aerobic and anaerobic performance of lower- and upper-body of Brazilian jiu-jitsu athletes.
Twelve male Brazilian jiu-jitsu athletes (26.3±6.6-years-old, 80.8±15.7kg) were assessed for lower- and upper-body aerobic and anaerobic fitness, body composition, squat jump, countermovement jump, and a plyometric push-up.
Higher values of aerobic fitness were obtained in the lower-body (treadmill: 45.6±8.4mL/kg/min) compared to the upper-body (arm cycloergometer: 36.6±6.1mL/kg/min) protocols in maximal graded exercise tests (GXT) (P=0.002). In Wingate tests, athletes reached 11.9±1.4W/kg for peak power and 8.4±1.0W/kg for mean power in the lower-body, and 10.5±1.0W/kg for peak power and 6.9±1.3W/kg for mean power in the upper-body. Athletes performed 37.8±7.4cm in squat jump, 41.5±10.0cm in countermovement jump, and 15.7±1.9cm in the plyometric push-up test. No significant correlations between absolute or relative measures of body composition (body fat mass and musculoskeletal mass) with aerobic (lower- and upper-body GXT) or anaerobic (lower- and upper-body Wingate and muscle power) performances were observed (P>0.05).
This study is new in describing upper-body aerobic and anaerobic performance in Brazilian jiu-jitsu athletes. In regards to aerobic and anaerobic performance of lower-body, results were similar to previous studies with Brazilian jiu-jitsu or other grappling combat sports athletes.
Étudier les performances aérobies et anaérobies des membres inférieurs et supérieurs des athlètes brésiliens de jiu-jitsu.
Douze athlètes masculins brésiliens de jiu-jitsu (26±7 ans, 80,8±15,7kg) ont été évalués pour la capacité aérobie et anaérobie des membres inférieurs et supérieurs, la composition corporelle, le saut vertical à partir d’une position accroupie, le saut en contre-mouvement et un push-up pliométrique.
Des valeurs plus élevées de la capacité aérobie ont été obtenues dans les membres inférieurs (tapis roulant : 45,6±8,4mL/kg/min) par rapport aux protocoles des membres supérieurs (cycloergomètre à bras : 36,6±6,1mL/kg/min) dans les tests d’effort maximal gradué (GXT) (p=0,002). Dans les tests Wingate, les athlètes ont atteint 11,9±1,4W/kg de puissance pic et 8,4±1,0W/kg de puissance moyenne dans les membres inférieurs, et 10,5±1,0W/kg de puissance pic et 6,9±1,3W/kg de puissance moyenne pour les membres supérieurs. Les athlètes ont atteint 37,8±7,4cm en saut accroupi, 41,5±10,0cm en saut à contre-mouvement et 15,7±1,9cm en le test de push |
---|---|
ISSN: | 0765-1597 |
DOI: | 10.1016/j.scispo.2021.03.006 |