Tubular solar air heater using finned semi-cylindrical absorber plate with swirl flow: Experimental investigation

•A tubular swirl-flow solar air heater (SF-SAH) with baffles is tested experimentally.•Radial baffles enhance SF-SAH performance compared to longitudinal baffles.•Increasing the number of radial baffles and air mass flow rate reduces the cost.•The proposed SF-SAH achieves thermohydraulic efficiency...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Solar energy 2022-04, Vol.236, p.879-897
Hauptverfasser: El-Said, Emad M.S., Abou Al-Sood, M.M., Elsharkawy, E.A., Abdelaziz, Gamal B.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•A tubular swirl-flow solar air heater (SF-SAH) with baffles is tested experimentally.•Radial baffles enhance SF-SAH performance compared to longitudinal baffles.•Increasing the number of radial baffles and air mass flow rate reduces the cost.•The proposed SF-SAH achieves thermohydraulic efficiency is about 72.40%.•The minimum estimated cost of heat unit production is about 0.0105 $/kW.hr.•The maximum effectiveness and exergy efficiency are about 0.6 and 1.3 % respectively. In this research, a tubular swirl-flow solar air heater (SF-SAH) with a find semi- cylindrical absorber plate is adopted to enhance its thermohydraulic performance. The proposed SF-SAH is tested with two types of fins: radial and longitudinal. Three sets of fins; 3, 4, and 5number of fins are tested. Data obtained from the proposed SF-SAH are compared with the plain duct conventional SF-SAH without fins under a typical air flow rate range 0.01–0.050 kg/s and Reynolds number (Re) from 7078 to 35190. Results obtained from this study reveal that radial fins enhance SF-SAH performance parameters when compared with the plain heater or heater with longitudinal fins. Also, increasing the number of radial fins and air flow rate enhances SF-SAH efficiency and Nusselt number and reduce the production cost. SF-SAH with five radial fins and air flow rate of 0.050 kg/s results maximum values for thermal and thermohydraulic efficiencies of 76.79%, 72.40%, respectively, Nusselt number of 223.64, and a minimum estimated production cost of 0.0105 $/kW.hr. The maximum effectiveness and exergy efficiency of SF-SAH are obtained with five radial fins and reached about 0.6 and 1.3 % respectively.
ISSN:0038-092X
1471-1257