Improvement of system strength under high wind penetration: A techno-economic assessment using synchronous condenser and SVC

Variable speed wind turbine generators (WTGs) are replacing traditional fossil fuel based synchronous generators in the generation fleet as wind penetration increases. These variable speed WTGs are decoupled from the grid by power electronics inverters and usually generate less fault current compare...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy (Oxford) 2022-05, Vol.246, p.123426, Article 123426
Hauptverfasser: Masood, Nahid-Al, Mahmud, Sajjad Uddin, Ansary, Md Nazmuddoha, Deeba, Shohana Rahman
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Variable speed wind turbine generators (WTGs) are replacing traditional fossil fuel based synchronous generators in the generation fleet as wind penetration increases. These variable speed WTGs are decoupled from the grid by power electronics inverters and usually generate less fault current compared to synchronous generators. As a result, system strength (indicates the fault recovery capability) at the point of common coupling (PCC) of wind power plants may reduce. A minimum value level of system strength is essential for wind power plants to properly identify and overcome a fault. To enhance system strength at wind PCC buses, supplementary devices such as synchronous condenser and Static VAR Compensator (SVC) can be deployed to have additional fault current. Since these devices are expensive, their optimal allocation considering economic feasibility is a major concern. In the existing literature, locations and ratings of the optimally allocated synchronous condenser are reported. However, this approach may cause oversizing of synchronous condensers. In addition, a SVC can be utilised instead of a synchronous condenser to enhance system strength. However, no detailed study is carried out yet to find the optimal size of SVCs. Evidently, both synchronous condenser and SVC can be installed to improve system strength. However, no comprehensive techno-economic assessment is performed for selecting an appropriate choice between them. To address these research gaps, this paper develops a framework to find the optimal sizes of synchronous condensers and SVCs by taking into account the long-term financial viability. Also, to ensure the maximum possible fault contribution, synchronous condensers/SVCs are connected directly to those wind PCC buses where system strength is below the acceptable limit. Afterwards, a detailed techno-economic assessment using synchronous condenser and SVC is performed in a wind dominated grid. In addition, post-fault voltage recovery characteristics with optimally sized synchronous condenser and SVC are explored. The developed methodology is applied to the IEEE 39 bus test system considering 45% wind power penetration scenario. Also, the performance of the proposed approach is compared to that of an existing technique. Finally, based on the technical and economic aspects, a better choice between synchronous condenser and SVC is recommended to improve system strength under high wind penetration. •System strength is improved in a wind domi
ISSN:0360-5442
1873-6785
DOI:10.1016/j.energy.2022.123426