A novel liquid air energy storage system using a combination of sensible and latent heat storage
•A stand-alone LAES system using sensible and latent heat store is proposed.•2-D numerical model is used to size the sensible heat store.•The PCM for latent heat store achieves a melting temperature of 110 K with 61.62 kJ/kg heat of fusion.•The round-trip efficiency of the stand-alone LAES system ha...
Gespeichert in:
Veröffentlicht in: | Applied thermal engineering 2022-02, Vol.203, p.117890, Article 117890 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •A stand-alone LAES system using sensible and latent heat store is proposed.•2-D numerical model is used to size the sensible heat store.•The PCM for latent heat store achieves a melting temperature of 110 K with 61.62 kJ/kg heat of fusion.•The round-trip efficiency of the stand-alone LAES system has been improved by 60.6%.
This paper proposes a novel stand-alone liquid air energy storage (LAES) system to enhance round-trip efficiency (RTE) using a thermal energy storage system. Thermal energy storage comprises sensible heat storage with quartz and latent heat storage with cryogenic phase change material (PCM) for recycling cold energy from the LAES discharge process. The liquid air in the pressurized tank was released during the discharge cycle and used to store energy using PCM and quartz. The cryogenic phase change material melts at 110 K based on experimental result, making it possible to provide cold heat of fusion 61.62 kJ/kg at a constant temperature for air liquefaction. Thus, proposed system can effectively increase the cold energy recycle. In addition, the two-dimension numerical model allowed us to estimate the outlet temperature of sensible heat store without isothermal assumption by Biot Number. The proposed process is modified from Linde-Hampson, and a sensitivity analysis is performed using ASPEN HYSYS. The analysis shows that the implementation of energy recycling from the compressor and thermal store leads to a high round-trip efficiency (60.6%) higher than base case (34.4%) of LAES system. Therefore, the proposed system is a promising process in terms of simplification and high efficiency, cognizant of the integration of waste heat from industrial plants. |
---|---|
ISSN: | 1359-4311 1873-5606 |
DOI: | 10.1016/j.applthermaleng.2021.117890 |