Feasibility of MOF-based carbon capture from indoor spaces as air revitalization system

[Display omitted] •Air revitalization system (ARS) is studied as a ventilation and cooling system.•ARS uses solid adsorbents to remove excess H2O and CO2 sequentially from indoor air.•ARS performance is compared to conventional systems using dehumidified ambient air.•Their performance is optimized f...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy and buildings 2022-01, Vol.255, p.111666, Article 111666
Hauptverfasser: Harrouz, Jean Paul, Ghali, Kamel, Hmadeh, Mohamad, Ghaddar, Nesreen, Ghani, Saud
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •Air revitalization system (ARS) is studied as a ventilation and cooling system.•ARS uses solid adsorbents to remove excess H2O and CO2 sequentially from indoor air.•ARS performance is compared to conventional systems using dehumidified ambient air.•Their performance is optimized for two case studies in Qatar: a classroom and a house.•ARS resulted in 91% and 71% reduction in fresh air intake, 30% and 24% energy savings. Conventional air-conditioning systems, for providing thermal comfort and acceptable indoor air quality, are energy intensive, especially for spaces located in hot and humid climates. This is attributed to the energy needed to offset the latent and sensible loads of the ambient air, which is typically achieved using a solid desiccant integrated with a vapor compression cooling. Air revitalization system (ARS) is proposed as an alternative solution to remove excess H2O and CO2 sequentially from the recirculated air using solid adsorbents such as silica gel for H2O and metal–organic frameworks (MOFs) for CO2. In this work, the feasibility of MOFs-based ARS is investigated by predicting its operational performance cost and compare it to the conventional system. Accordingly, mathematical models were developed for the adsorption beds and the indoor space and integrated to genetic algorithm. The integrated model was used to properly size and optimize the system for a classroom and a residential house located in the Qatari climate. The simulation results showed that the ARS decreased the fresh air intake by 91% and 71%, for the classroom and house, respectively, leading to savings of 30% and 24% as well as payback periods of 5 and 2 years compared to the conventional system.
ISSN:0378-7788
1872-6178
DOI:10.1016/j.enbuild.2021.111666