Decontamination of corrosion oxides in the heat transport system of a pressurized heavy water reactor using chelate-free inorganic acid

Thick corrosion oxide (Fe 3 O 4 ) layers containing radioactive metals are generated in a carbon steel heat transport system (HTS) of pressurized heavy water reactors during operation. It is necessary to decontaminate the oxide layers to reduce radiation exposure to workers before maintenance and de...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of nuclear science and technology 2022-03, Vol.59 (3), p.306-317
Hauptverfasser: Chang, Naon, Eun, Heechul, Kim, Seonbyeong, Seo, Bumkyung, Kim, Yongsoo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Thick corrosion oxide (Fe 3 O 4 ) layers containing radioactive metals are generated in a carbon steel heat transport system (HTS) of pressurized heavy water reactors during operation. It is necessary to decontaminate the oxide layers to reduce radiation exposure to workers before maintenance and decommissioning. Since the oxide layer thickness in the HTS is about 75 μm, a considerable amounts of secondary wastes can be generated when the existing decontamination processes are applied. The aim of this study is to design a chemical decontamination process using chelate-free inorganic acid that can be effectively applied to remove the oxide layers in the HTS and to minimize the secondary waste generation. Therefore, Fe 3 O 4 dissolution behaviors were evaluated in a Hydrazine Based Reductive metal Ion Decontamination (HyBRID) process using the chelate-free inorganic acid. From this result, the decontamination process of oxide layers in the HTS using recycling of decontamination process solution and the process control method using pH monitoring were constructed. In particular, process control based on pH monitoring can be easily used because decontamination performance can be controlled according to the goal; (1) effective removing the oxide layer at decommissioning, (2) avoiding corrosion of base metal and removing the oxide layer at maintenance.
ISSN:0022-3131
1881-1248
DOI:10.1080/00223131.2021.1964404