Sensitivity adjustable biosensor based on graphene oxide coated excessively tilted fiber grating

Biosensors play a significant role in biomedical, clinical and disease diagnosis areas. Here, we proposed Langmuir adsorption model to explain sensing mechanism of biosensor based on excessively tilted fiber grating (Ex-TFG) functionalized with graphene oxide (GO). Due to GO containing plenty of six...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2022-01, Vol.351, p.130832, Article 130832
Hauptverfasser: Sun, Yuezhen, Guo, Xiaoxia, Moreno, Yarien, Sun, Qizhen, Yan, Zhijun, Zhang, Lin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Biosensors play a significant role in biomedical, clinical and disease diagnosis areas. Here, we proposed Langmuir adsorption model to explain sensing mechanism of biosensor based on excessively tilted fiber grating (Ex-TFG) functionalized with graphene oxide (GO). Due to GO containing plenty of six-membered rings and oxygen-containing groups, the biomolecules can be easily adsorbed through π-π interaction and hydrogen bond. The whole interaction process obeys the Langmuir adsorption model in which there always an equilibrium during detecting process, inducing the sensor with adjustable bio-sensitivity and detection range. Three biosensors based on Ex-TFG coated with three different amount of GO were investigated for hemoglobin (Hb) detection experiment, showing pronounced bio-interaction induced resonance shifts. The experiment results indicate that GO coating could enhance the surface biological activity of Ex-TFG, making the Ex-TFG sensitive to the Hb biomolecule solutions. The three GO coated Ex-TFG sensors have the bio-sensitivity of 3.83 nm/(mg/ml), 4.33 nm/(mg/ml), and 8.21 nm/(mg/ml), and the detection range of 0.8 mg/ml, 0.6 mg/ml and 0.4 mg/ml, respectively, which are in good agreement with the prediction from the Langmuir adsorption model. By controlling the amount of the bio-functionalized materials, the bio-sensitivity and detection range of the Ex-TFG based biosensors can be easily adjusted. •Proposed GO functionalized Ex-TFG based low temperature crosstalk biosensor for biomolecules probing.•For the first time, established Langmuir adsorption law based sensing model of optical fiber biosensor.•Achieved the sensitivity and detection range adjustable biosensor.
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2021.130832