Optimization of a multi-generation power, desalination, refrigeration and heating system
The optimization of a multi-generation system which represents the integrated dual-purpose desalination plant and a low-scale absorption refrigeration system is addressed. A nonlinear mathematical programming optimization model that integrates a natural gas combined-cycle, a multi-effect distillatio...
Gespeichert in:
Veröffentlicht in: | Energy (Oxford) 2022-01, Vol.238, p.121737, Article 121737 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The optimization of a multi-generation system which represents the integrated dual-purpose desalination plant and a low-scale absorption refrigeration system is addressed. A nonlinear mathematical programming optimization model that integrates a natural gas combined-cycle, a multi-effect distillation desalination plant, a series flow double-effect water-lithium bromide absorption refrigeration system, and a water heater, is developed based on first-principle models. The model is implemented in General Algebraic Modelling System and a generalized gradient-based optimization algorithm is used.
Given design specifications for electricity generation (around 37 MW), freshwater production (100 kg/s), refrigeration capacity (2 MW), and thermal load for heating (around 0.7 MW of hot water), the integrated system is optimized by minimizing two objective functions by single-objective optimization: total heat transfer area and total annual cost. As a result, minimum total heat transfer area values of 39148 m2, 36002 m2, and 35161 m2 are obtained when 4, 5, and 6 distillation effects were considered in the multi-effect distillation system, respectively. Also, a minimum annual cost of around 24 MM$/yr. is obtained for 5 distillation effects.
The influence of the number of effects in the multi-effect distillation subsystem on the optimal solutions is analyzed. Cost-effective optimal solutions are developed for the studied multi-generation system.
•A multi-generation system is integrated for power, freshwater, cooling, and heating.•NLP model for simultaneous optimization is proposed and gradient-based method is used.•The total heat transfer area (THTA) of the entire process is minimized.•The total annual cost (TAC) of the entire process is minimized.•A minimum TAC of 23.9 MM$/yr. is found when five-effect MED desalination unit is used. |
---|---|
ISSN: | 0360-5442 1873-6785 |
DOI: | 10.1016/j.energy.2021.121737 |