Effects of electroactive group and enzyme crosslinkers numbers on analytical performance for conductive polymer-based sensor platforms

This manuscript describes an amperometric sensor application of a new class of triazine-centered monomers functionalized with different numbers of carbazole and hydrazine. In the sensor system, carbazole and hydrazine are designed as transducer and enzyme crosslinker groups, respectively. The monome...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Reactive & functional polymers 2021-11, Vol.168, p.105038, Article 105038
Hauptverfasser: Soganci Aras, Tugba, Durur Gumusay, Simge, Ak, Metin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This manuscript describes an amperometric sensor application of a new class of triazine-centered monomers functionalized with different numbers of carbazole and hydrazine. In the sensor system, carbazole and hydrazine are designed as transducer and enzyme crosslinker groups, respectively. The monomers (TECA and CTDA) containing different numbers of carbazole and hydrazine were electrochemically polymerized on a graphite (GR) electrode. A new sensor platforms for glucose determination have been obtained by immobilizing glucose oxidase (GOx) on the polymer film surfaces. The pTECA/GOx and pCTDA/GOx-based electrodes were investigated for an evaluation of electron transfer between the enzyme and electrode at bioelectrochemically relevant potentials via pTECA and pCTDA layer. The results show that amperometric response values were greater for the polymer containing more hydrazine ends than the polymer containing more carbazole groups. This is due to the that as the hydrazine ends increased, the more enzyme crosslinker groups at the same surface size. The evaluation of two different configurations (pTECA/GOx and pCTDA/GOx) of working electrodes suggested that the pTECA/GOx configuration, which was composed of more hydrazine ends and enzyme, is the more suitable candidate for biosensor applications. Moreover, it was determined that the pTECA/GOx and pCTDA/GOx-based electrodes are reliable for the establishment of advanced electron transfer between enzyme and electrode for the application in amperometric biosensors because of the observed high amperometric response values, and low LOD values. [Display omitted] •New class of triazine-centered monomers were clarified.•The created biosensor platforms show good detection performance.
ISSN:1381-5148
1873-166X
DOI:10.1016/j.reactfunctpolym.2021.105038