Organization of Counter-Mixing of Ozone Flows and Aqueous Solutions
The dissolution of concentrated ozone in water at liquid and gas counter-flows has been studied. It was shown that the ozone flow rate can be increased from 0.042 cm 3 /s cm 2 (flotation treatment of water with ozone) to 3.6 cm 3 /s cm 2 (counter-flow). A scheme of counter-mixing of ozone in gas wit...
Gespeichert in:
Veröffentlicht in: | Theoretical foundations of chemical engineering 2021-07, Vol.55 (4), p.846-849 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The dissolution of concentrated ozone in water at liquid and gas counter-flows has been studied. It was shown that the ozone flow rate can be increased from 0.042 cm
3
/s cm
2
(flotation treatment of water with ozone) to 3.6 cm
3
/s cm
2
(counter-flow). A scheme of counter-mixing of ozone in gas with water without using flotation technology was suggested. The optimum ratio of ozone carrier gas to water was found to be 1 : 3. The ozone concentration at the reactor outlet was 8 mg/dm
3
(4%), and the concentration of ozone dissolved in water reached 45 mg/dm
3
. A scheme of a unit for counter-mixing of ozone in gas with water was proposed. |
---|---|
ISSN: | 0040-5795 1608-3431 |
DOI: | 10.1134/S0040579521040047 |