Label-free detection of target proteins using peptide molecular wires as conductive supports

[Display omitted] •Conductive peptide molecular wires were developed for electrochemical detection.•Peptide wires successfully replace thiols for electrode coating and ligand immobilization.•Tumor-associated carbohydrate antigen mimetic and Growth Hormone Secretagogue receptor agonists were detected...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sensors and actuators. B, Chemical Chemical, 2021-10, Vol.345, p.130416, Article 130416
Hauptverfasser: Puiu, Mihaela, Zamfir, Lucian-Gabriel, Danila, George Madalin, Papi, Francesco, Nativi, Cristina, Mirceski, Valentin, Bala, Camelia
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •Conductive peptide molecular wires were developed for electrochemical detection.•Peptide wires successfully replace thiols for electrode coating and ligand immobilization.•Tumor-associated carbohydrate antigen mimetic and Growth Hormone Secretagogue receptor agonists were detected. We report on the electrochemistry of a peptide molecular wire as a conductive support for ligand immobilization in biosensing assays. The helical 9-mer peptide, tagged at Nterminus with Methylene Blue (MB) and thiol-functionalized at Cterminus was anchored on a gold surface via gold/thiol chemistry. The helical peptide acts as molecular wire, mediating the two-step electron transfer (ET) from MB to the gold surface. The forward and backward square wave voltametric (SWV) components recorded in the presence of peptide wire were used to estimate the kinetic parameters of the electrode reaction. The simulated data matched the experimental ones for the two-step sequential surface mechanism (EE), with the rate constant of the first step ksur,1 = 20 s−1 and the cathodic ET coefficient α1 = 0.55. The kinetic parameters of the second step were ksur,2 > 1000 s−1, and α2 = 0.5. Small ligands for high-molecular weight targets can be grafted on the peptide wire between the MB tag and the surface through covalent bonding. The binding of the target to the peptide-anchored ligand hampers the ET transfer from MB to the electrode surface, causing a decrease of the peak current. These findings were used further to develop an electrochemical peptide-based biosensor with signaling-off interrogation. The biosensor was tested against two relevant targets for medical diagnosis: the anti-tumor-associated carbohydrate antigen (α-Tn) antibody and the growth hormone secretagogue receptor (GHS-R1a), after ligand grafting. Both targets were detected in the nanomolar range with an overall assay time of 10 min.
ISSN:0925-4005
1873-3077
DOI:10.1016/j.snb.2021.130416