Analytical quality by design approach for the control of potentially counterfeit chloroquine with some NSAIDS using HPLC with fluorescence detection in pharmaceutical preparation and breast milk
Chloroquine phosphate (CQ) the antimalarial drug and suggested to treat the pandemic disease coronavirus (COVID-19) is often adulterated with some of the non-steroidal anti-inflammatory drugs (NSAIDs) such as paracetamol, aspirin (ASP), or both. The purpose of this study is to detect such counterfei...
Gespeichert in:
Veröffentlicht in: | Acta chromatographica 2021-09, Vol.33 (3), p.234-244 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Chloroquine phosphate (CQ) the antimalarial drug and suggested to treat the pandemic disease coronavirus (COVID-19) is often adulterated with some of the non-steroidal anti-inflammatory drugs (NSAIDs) such as paracetamol, aspirin (ASP), or both. The purpose of this study is to detect such counterfeited drugs, using a reversed phase high pressure liquid chromatography (RP-HPLC) method with fluorescence detection. Analysis was divided into three phases. In the first phase, a Plackett-Burman design (PBD) was used to screen five independent factors, namely, buffer pH, buffer concentration (mM), acetonitrile content (%), flow rate (mL/min) and triethylamine (TEA) content in the buffer preparation (%). The selected dependent variables were (resolution, symmetry of peaks and run time). The objective of the second phase was to optimize the method performance using Box-Behnken design (BBD) and desirability function for multiple response optimization to obtain the best chromatographic performance with the shortest run time. Optimal chromatographic separation was achieved on a YMC-pack pro C18 ODS-A column (15 cm × 4.6 mm, 5 µm) at room temperature The optimum mobile phase consisted of acetonitrile and 5 mM sodium dihydrogen phosphate buffer containing 0.5% triethyamine (30:70, v/v) with the pH adjusted to 3.5 using an orthophosphoric acid solution. The flow rate was maintained at 1 mL/min, and the detection was performed with a fluorescence detector fixed at 380 nm (λ
emission
) after excitation at 335 nm (λ
excitation
). The third phase was method validation according to ICH guidelines, providing to be specific, precise, accurate, and robust. The method is linear over a range of 0.4–8 µg/mL for chloroquine and ASP, while for paracetamol it is linear over 16–48 µg/mL. The developed RP-HPLC method was used for quantitation of the three drugs in chloroquine dosage form samples. The method shows a great tendency in the classification between the genuine chloroquine and the adulterated ones in pharmaceutical preparations and breast milk. |
---|---|
ISSN: | 1233-2356 2083-5736 |
DOI: | 10.1556/1326.2020.00793 |