Mcu-PD Code Calculation of Personnel Irradiation Dose in an Accident with Coolant Leakage in Serviced Enclosures in NPP with VVER-1000

Calculations of the personnel irradiation dose rate were performed to assess the radiation consequences of the rupturing of a tube in the sampling line in a complex preparing samples for automated chemical monitoring of the primary loop of NPP with VVER-1000. The calculations were performed by the M...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Atomic energy (New York, N.Y.) N.Y.), 2021-05, Vol.130 (1), p.40-44
Hauptverfasser: Oleynik, D. S., Saprykin, D. K., Sergeev, G. S., Shkarovsky, D. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Calculations of the personnel irradiation dose rate were performed to assess the radiation consequences of the rupturing of a tube in the sampling line in a complex preparing samples for automated chemical monitoring of the primary loop of NPP with VVER-1000. The calculations were performed by the Monte Carlo method using the MCU-PD high-precision code based on data on the activity of fission products in the primary coolant using ICRP-developed anthropomorphic voxel-phantoms of a standard person.
ISSN:1063-4258
1573-8205
DOI:10.1007/s10512-021-00771-2