Fault Detection of Circulation Pumps on the Basis of Motor Current Evaluation

Motor current signature analysis (MCSA) for fault detection has found widespread application, especially for induction motors. The basis of MCSA is the evaluation of a motor's current. This analysis is now also used for other motor types and can be used to detect faults of the coupled load. The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IEEE transactions on industry applications 2021-09, Vol.57 (5), p.4617-4624
Hauptverfasser: Becker, Vincent, Schwamm, Thilo, Urschel, Sven, Antonino-Daviu, Jose
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Motor current signature analysis (MCSA) for fault detection has found widespread application, especially for induction motors. The basis of MCSA is the evaluation of a motor's current. This analysis is now also used for other motor types and can be used to detect faults of the coupled load. The purpose of this article is to examine whether MCSA can be used to detect faults in a wet-rotor pump. A total of three faults are examined. The results show that, compared with a healthy pump, all faults could be detected. However, a detailed analysis of frequency components has to be carried out to differentiate the faults. A circulation pump with a maximum power consumption of 1.1 kW was used as the test item.
ISSN:0093-9994
1939-9367
DOI:10.1109/TIA.2021.3085697