Automatic device for indirect measurement of leakage flow rate in compressed air pipeline

The new measurement method of compressed air leakage flow rate in compressed air pipeline is proposed. In this method, the automatic measuring device is connected to a branch of the pipeline. The measuring device can be used to measure compressed air leakage in any place of compressed air pipeline:...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Materials Science and Engineering 2017-08, Vol.233 (1), p.12030
Hauptverfasser: Dindorf, R, Wos, P, Pawelec, K
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The new measurement method of compressed air leakage flow rate in compressed air pipeline is proposed. In this method, the automatic measuring device is connected to a branch of the pipeline. The measuring device can be used to measure compressed air leakage in any place of compressed air pipeline: in main line, distribution line and connection line. The proposed measurement methods of compressed air leakage in pipeline are independent of receiver and compressor parameters, which is not the case with traditional method measuring leaks by emptying the receiver.