Determination of enamel insulation corona resistance by high- frequency modulated pulses

In the article test equipment is described for corona resistance testing of enameled winding wire samples. The primary element of equipment is generator producing test voltage with necessary waveform and magnitude according to the required PWM. Test conditions are accurately simulated by operational...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Materials Science and Engineering 2015-04, Vol.81 (1), p.12094
Hauptverfasser: Leonov, A P, Red'ko, V V, Red'ko, L A, Soldatenko, E Y
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In the article test equipment is described for corona resistance testing of enameled winding wire samples. The primary element of equipment is generator producing test voltage with necessary waveform and magnitude according to the required PWM. Test conditions are accurately simulated by operational loads on a winding insulation (simultaneous impact of temperature and corona discharges). Obtained results of average time to breakdown show that the enamel insulation modified by silicon nanoparticles has a maximum corona resistance.
ISSN:1757-8981
1757-899X
1757-899X
DOI:10.1088/1757-899X/81/1/012094