Thermohydraulic modelling of a transfer line for continuous flow cryostats
Continuous flow cryostats have to be steadily supplied with the cryogenic cooling agent, e.g. liquid helium (LHe) via a transfer line. The overall setup has to be characterised by a low consumption of the cryogen, determined not only by the cryostat design, but also by the transfer line design. In o...
Gespeichert in:
Veröffentlicht in: | IOP conference series. Materials Science and Engineering 2017-02, Vol.171 (1), p.12129 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Continuous flow cryostats have to be steadily supplied with the cryogenic cooling agent, e.g. liquid helium (LHe) via a transfer line. The overall setup has to be characterised by a low consumption of the cryogen, determined not only by the cryostat design, but also by the transfer line design. In order to improve the transfer line's performance, i.e. reducing the evaporation losses a thermohydraulic model has been developed to evaluate different transfer line designs. The presented model is validated by experimental data achieved with a transfer line equipped with built-in pressure sensors. This transfer line has been designed in order to examine the related frictional pressure drop. The developed model allows to examine the impact of the hydraulic and the insulation design on the resulting evaporation losses. |
---|---|
ISSN: | 1757-8981 1757-899X |
DOI: | 10.1088/1757-899X/171/1/012129 |