Modeling and Simulation Analysis of Pre-Valve Compensation of Flow-saturated Resistant System

The load-sensing pre-valve compensation technology is widely used in the single-pump multi-acting mechanism composite motion circuit. Due to the use of multi-valve inlet valve front compensation, its structure is simple, only need to set a two-way fixed-rate valve, but the flow saturation conditions...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Materials Science and Engineering 2020-01, Vol.735 (1), p.12071
Hauptverfasser: Luo, Yanlei, Chen, Wang, Chi, Baokun
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The load-sensing pre-valve compensation technology is widely used in the single-pump multi-acting mechanism composite motion circuit. Due to the use of multi-valve inlet valve front compensation, its structure is simple, only need to set a two-way fixed-rate valve, but the flow saturation conditions cannot be automatically adjusted. Through an in-depth theoretical analysis of the anti-saturation mechanism, composition and control strategy principle based on automatic flow reduction (AVR), the AMESim model of the system is established, and the anti-flow-saturation output characteristics of the system are obtained under different operating conditions by numerical simulation means, and the results show that the system can solve the problem of flow-saturation. It provides some technical reference for the design of the load-sensing pre-valve compensation system.
ISSN:1757-8981
1757-899X
DOI:10.1088/1757-899X/735/1/012071