House-scale Renewable Energy System Sizing in Liverpool
Renewable energy technology such as solar thermal, PV, and wind have been developed to be building integrated. This exercise is aimed to sizing those three renewable energy systems for a typical house in the UK, specifically Liverpool. The methodologies used in this exercise are load evaluation, res...
Gespeichert in:
Veröffentlicht in: | IOP conference series. Earth and environmental science 2019-06, Vol.291 (1), p.12028 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Renewable energy technology such as solar thermal, PV, and wind have been developed to be building integrated. This exercise is aimed to sizing those three renewable energy systems for a typical house in the UK, specifically Liverpool. The methodologies used in this exercise are load evaluation, resource assessment, and finally sizing the systems. The results from all of sizing calculation show that there will be 6 evacuated tube collectors with 6m2 area, 14 PV modules with 20.7 m2 area, and 1 wind turbine with 2.5 rotor diameter. The renewable energy systems for electricity sized are predicted to cover 78.47% of the electricity load with PV contribution as many as 54.5% and the rest 24% is covered by wind turbine. |
---|---|
ISSN: | 1755-1307 1755-1315 |
DOI: | 10.1088/1755-1315/291/1/012028 |