Study building heat storage operation strategy for air-to-water heat pumps connected to a residential floor heating system

A transient simulation model of floor radiant heating system with air-to-water heat pumps for a 100 m2 building in the Beijing rural area was developed by using TRNSYS software, and combining the Hooke-Jeeves algorithm on the GenOpt platform, the influence of building exterior wall insulation on bui...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Earth and environmental science 2019-02, Vol.227 (4), p.42054
Hauptverfasser: Jiang, Duhui, Cui, Hongshe, Jiang, Kaidi, Yang, Jialin
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A transient simulation model of floor radiant heating system with air-to-water heat pumps for a 100 m2 building in the Beijing rural area was developed by using TRNSYS software, and combining the Hooke-Jeeves algorithm on the GenOpt platform, the influence of building exterior wall insulation on building heat storage strategy of the floor radiant heating system with air-to-water heat pumps was studied on the current peak and valley period electricity price. The law of the best heat-lag temperature and heat-lag time was obtained under different building exterior wall insulation method and thickness by optimizing the whole heating season operation cost.
ISSN:1755-1307
1755-1315
1755-1315
DOI:10.1088/1755-1315/227/4/042054