Study on Surface Quality of Acetabular Reaming in Total Hip Replacement

The surface quality of the acetabular reaming during total hip replacement is an important factor affecting the initial stability and bone ingrowth of the acetabular prosthesis. Two parameters – the unresectioned maximum height hl and area A of cross-sectional area – are defined to evaluate the surf...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ji xie gong cheng xue bao 2021, Vol.57 (11), p.93
Hauptverfasser: Sui, Jianbo, Guo, Kaijie, Luo, Jiaqi, Chen, Zhihua, Liu, Zhihua, Wang, Chengyong, Chen, Bin
Format: Artikel
Sprache:chi ; eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue 11
container_start_page 93
container_title Ji xie gong cheng xue bao
container_volume 57
creator Sui, Jianbo
Guo, Kaijie
Luo, Jiaqi
Chen, Zhihua
Liu, Zhihua
Wang, Chengyong
Chen, Bin
description The surface quality of the acetabular reaming during total hip replacement is an important factor affecting the initial stability and bone ingrowth of the acetabular prosthesis. Two parameters – the unresectioned maximum height hl and area A of cross-sectional area – are defined to evaluate the surface quality of acetabular reaming, an analytical model of the surface quality is proposed based the these two parameters for acetabular reaming, the influence of the various structural parameters of the acetabular reamer on the surface quality is studied based on the analytical model, and an acetabular reamer with new structural parameters is proposed based on the investigation, and manufactured with 3D printing technology, and verified with experiments. The results show that the predicted results of the proposed analytical model of surface quality of acetabular reaming are consistent with the experimental results. The predicted error of the maximum height is less than 4.4%, and the predicted error of the unresectioned area is less than 6.2%. The quantity, tooth profile and arrangement of the cutting teeth have a significant impact on the surface quality. The surface quality of acetabular reaming can be improved effectively by the acetabular reamer with new structural parameters, and the initial stability and bone ingrowth of the acetabular prosthesis can be enhanced, and the early fixation failure of the acetabular prosthesis can be avoided and the quality of surgery can be improved correspondingly.
doi_str_mv 10.3901/JME.2021.11.093
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_journals_2557257505</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2557257505</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1093-73b81438917209584166192d11aacc55bcd8058f6d1d117a034839e8cfe56c1c3</originalsourceid><addsrcrecordid>eNotkD1PwzAQhj2ARCnMrJaYk_rs-GusqtKCihC0zJbjOChVmgTHGfrvcVWmkx69d_fqQegJSM40gcXb-zqnhEIOkBPNbtCMcCkzIZS4Q_fjeCSEaUlhhjb7OFVn3Hd4P4XaOo8_J9s2MaEaL52PtpxaG_CXt6em-8FNhw99tC3eNkOCQ5tWTr6LD-i2tu3oH__nHH2_rA-rbbb72LyulrvMQSqSSVYqKJjSICnRXBUgBGhaAVjrHOelqxThqhYVJCYtYYVi2itXey4cODZHz9e7Q-h_Jz9Gc-yn0KWXhnIuKZec8JRaXFMu9OMYfG2G0JxsOBsg5mLIJEPmYsgAmFSM_QE5PVix</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2557257505</pqid></control><display><type>article</type><title>Study on Surface Quality of Acetabular Reaming in Total Hip Replacement</title><source>Alma/SFX Local Collection</source><creator>Sui, Jianbo ; Guo, Kaijie ; Luo, Jiaqi ; Chen, Zhihua ; Liu, Zhihua ; Wang, Chengyong ; Chen, Bin</creator><creatorcontrib>Sui, Jianbo ; Guo, Kaijie ; Luo, Jiaqi ; Chen, Zhihua ; Liu, Zhihua ; Wang, Chengyong ; Chen, Bin</creatorcontrib><description>The surface quality of the acetabular reaming during total hip replacement is an important factor affecting the initial stability and bone ingrowth of the acetabular prosthesis. Two parameters – the unresectioned maximum height hl and area A of cross-sectional area – are defined to evaluate the surface quality of acetabular reaming, an analytical model of the surface quality is proposed based the these two parameters for acetabular reaming, the influence of the various structural parameters of the acetabular reamer on the surface quality is studied based on the analytical model, and an acetabular reamer with new structural parameters is proposed based on the investigation, and manufactured with 3D printing technology, and verified with experiments. The results show that the predicted results of the proposed analytical model of surface quality of acetabular reaming are consistent with the experimental results. The predicted error of the maximum height is less than 4.4%, and the predicted error of the unresectioned area is less than 6.2%. The quantity, tooth profile and arrangement of the cutting teeth have a significant impact on the surface quality. The surface quality of acetabular reaming can be improved effectively by the acetabular reamer with new structural parameters, and the initial stability and bone ingrowth of the acetabular prosthesis can be enhanced, and the early fixation failure of the acetabular prosthesis can be avoided and the quality of surgery can be improved correspondingly.</description><identifier>ISSN: 0577-6686</identifier><identifier>DOI: 10.3901/JME.2021.11.093</identifier><language>chi ; eng</language><publisher>Beijing: Chinese Mechanical Engineering Society (CMES)</publisher><subject>Biomedical materials ; Mathematical models ; Orthopaedic implants ; Parameters ; Prostheses ; Rapid prototyping ; Reaming ; Surface properties ; Three dimensional printing</subject><ispartof>Ji xie gong cheng xue bao, 2021, Vol.57 (11), p.93</ispartof><rights>Copyright Chinese Mechanical Engineering Society (CMES) 2021</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids></links><search><creatorcontrib>Sui, Jianbo</creatorcontrib><creatorcontrib>Guo, Kaijie</creatorcontrib><creatorcontrib>Luo, Jiaqi</creatorcontrib><creatorcontrib>Chen, Zhihua</creatorcontrib><creatorcontrib>Liu, Zhihua</creatorcontrib><creatorcontrib>Wang, Chengyong</creatorcontrib><creatorcontrib>Chen, Bin</creatorcontrib><title>Study on Surface Quality of Acetabular Reaming in Total Hip Replacement</title><title>Ji xie gong cheng xue bao</title><description>The surface quality of the acetabular reaming during total hip replacement is an important factor affecting the initial stability and bone ingrowth of the acetabular prosthesis. Two parameters – the unresectioned maximum height hl and area A of cross-sectional area – are defined to evaluate the surface quality of acetabular reaming, an analytical model of the surface quality is proposed based the these two parameters for acetabular reaming, the influence of the various structural parameters of the acetabular reamer on the surface quality is studied based on the analytical model, and an acetabular reamer with new structural parameters is proposed based on the investigation, and manufactured with 3D printing technology, and verified with experiments. The results show that the predicted results of the proposed analytical model of surface quality of acetabular reaming are consistent with the experimental results. The predicted error of the maximum height is less than 4.4%, and the predicted error of the unresectioned area is less than 6.2%. The quantity, tooth profile and arrangement of the cutting teeth have a significant impact on the surface quality. The surface quality of acetabular reaming can be improved effectively by the acetabular reamer with new structural parameters, and the initial stability and bone ingrowth of the acetabular prosthesis can be enhanced, and the early fixation failure of the acetabular prosthesis can be avoided and the quality of surgery can be improved correspondingly.</description><subject>Biomedical materials</subject><subject>Mathematical models</subject><subject>Orthopaedic implants</subject><subject>Parameters</subject><subject>Prostheses</subject><subject>Rapid prototyping</subject><subject>Reaming</subject><subject>Surface properties</subject><subject>Three dimensional printing</subject><issn>0577-6686</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNotkD1PwzAQhj2ARCnMrJaYk_rs-GusqtKCihC0zJbjOChVmgTHGfrvcVWmkx69d_fqQegJSM40gcXb-zqnhEIOkBPNbtCMcCkzIZS4Q_fjeCSEaUlhhjb7OFVn3Hd4P4XaOo8_J9s2MaEaL52PtpxaG_CXt6em-8FNhw99tC3eNkOCQ5tWTr6LD-i2tu3oH__nHH2_rA-rbbb72LyulrvMQSqSSVYqKJjSICnRXBUgBGhaAVjrHOelqxThqhYVJCYtYYVi2itXey4cODZHz9e7Q-h_Jz9Gc-yn0KWXhnIuKZec8JRaXFMu9OMYfG2G0JxsOBsg5mLIJEPmYsgAmFSM_QE5PVix</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Sui, Jianbo</creator><creator>Guo, Kaijie</creator><creator>Luo, Jiaqi</creator><creator>Chen, Zhihua</creator><creator>Liu, Zhihua</creator><creator>Wang, Chengyong</creator><creator>Chen, Bin</creator><general>Chinese Mechanical Engineering Society (CMES)</general><scope>AAYXX</scope><scope>CITATION</scope><scope>7TB</scope><scope>8FD</scope><scope>FR3</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>2021</creationdate><title>Study on Surface Quality of Acetabular Reaming in Total Hip Replacement</title><author>Sui, Jianbo ; Guo, Kaijie ; Luo, Jiaqi ; Chen, Zhihua ; Liu, Zhihua ; Wang, Chengyong ; Chen, Bin</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1093-73b81438917209584166192d11aacc55bcd8058f6d1d117a034839e8cfe56c1c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>chi ; eng</language><creationdate>2021</creationdate><topic>Biomedical materials</topic><topic>Mathematical models</topic><topic>Orthopaedic implants</topic><topic>Parameters</topic><topic>Prostheses</topic><topic>Rapid prototyping</topic><topic>Reaming</topic><topic>Surface properties</topic><topic>Three dimensional printing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Sui, Jianbo</creatorcontrib><creatorcontrib>Guo, Kaijie</creatorcontrib><creatorcontrib>Luo, Jiaqi</creatorcontrib><creatorcontrib>Chen, Zhihua</creatorcontrib><creatorcontrib>Liu, Zhihua</creatorcontrib><creatorcontrib>Wang, Chengyong</creatorcontrib><creatorcontrib>Chen, Bin</creatorcontrib><collection>CrossRef</collection><collection>Mechanical &amp; Transportation Engineering Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>Ji xie gong cheng xue bao</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Sui, Jianbo</au><au>Guo, Kaijie</au><au>Luo, Jiaqi</au><au>Chen, Zhihua</au><au>Liu, Zhihua</au><au>Wang, Chengyong</au><au>Chen, Bin</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Study on Surface Quality of Acetabular Reaming in Total Hip Replacement</atitle><jtitle>Ji xie gong cheng xue bao</jtitle><date>2021</date><risdate>2021</risdate><volume>57</volume><issue>11</issue><spage>93</spage><pages>93-</pages><issn>0577-6686</issn><abstract>The surface quality of the acetabular reaming during total hip replacement is an important factor affecting the initial stability and bone ingrowth of the acetabular prosthesis. Two parameters – the unresectioned maximum height hl and area A of cross-sectional area – are defined to evaluate the surface quality of acetabular reaming, an analytical model of the surface quality is proposed based the these two parameters for acetabular reaming, the influence of the various structural parameters of the acetabular reamer on the surface quality is studied based on the analytical model, and an acetabular reamer with new structural parameters is proposed based on the investigation, and manufactured with 3D printing technology, and verified with experiments. The results show that the predicted results of the proposed analytical model of surface quality of acetabular reaming are consistent with the experimental results. The predicted error of the maximum height is less than 4.4%, and the predicted error of the unresectioned area is less than 6.2%. The quantity, tooth profile and arrangement of the cutting teeth have a significant impact on the surface quality. The surface quality of acetabular reaming can be improved effectively by the acetabular reamer with new structural parameters, and the initial stability and bone ingrowth of the acetabular prosthesis can be enhanced, and the early fixation failure of the acetabular prosthesis can be avoided and the quality of surgery can be improved correspondingly.</abstract><cop>Beijing</cop><pub>Chinese Mechanical Engineering Society (CMES)</pub><doi>10.3901/JME.2021.11.093</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0577-6686
ispartof Ji xie gong cheng xue bao, 2021, Vol.57 (11), p.93
issn 0577-6686
language chi ; eng
recordid cdi_proquest_journals_2557257505
source Alma/SFX Local Collection
subjects Biomedical materials
Mathematical models
Orthopaedic implants
Parameters
Prostheses
Rapid prototyping
Reaming
Surface properties
Three dimensional printing
title Study on Surface Quality of Acetabular Reaming in Total Hip Replacement
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T01%3A51%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Study%20on%20Surface%20Quality%20of%20Acetabular%20Reaming%20in%20Total%20Hip%20Replacement&rft.jtitle=Ji%20xie%20gong%20cheng%20xue%20bao&rft.au=Sui,%20Jianbo&rft.date=2021&rft.volume=57&rft.issue=11&rft.spage=93&rft.pages=93-&rft.issn=0577-6686&rft_id=info:doi/10.3901/JME.2021.11.093&rft_dat=%3Cproquest_cross%3E2557257505%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2557257505&rft_id=info:pmid/&rfr_iscdi=true