Determination of the Dynamic Rigidity of Magnetic Controllable Hydromount Dependence on the Frequency of Vibration

Building damping characteristic of magnetocontrollable hydromounts and their correlational relationship with dynamic rigidity is considered in this article. Damping characteristics of hydromounts primarily comprise their amplitude-frequency characteristics (AFC). Building damping characteristics of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Earth and environmental science 2020-04, Vol.459 (6), p.62094
Hauptverfasser: Gordeev, B, Okhulkov, S, Ermolaev, A, Titov, D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Building damping characteristic of magnetocontrollable hydromounts and their correlational relationship with dynamic rigidity is considered in this article. Damping characteristics of hydromounts primarily comprise their amplitude-frequency characteristics (AFC). Building damping characteristics of magnetocontrollable hydromounts unaffected by magnetic field was performed basing on vibration tests data on vibrostand Star28, generating broadband random vibration (Random), in order to determine their resonance frequencies at 50 m/s2 input root-mean-square vibration acceleration (RMS).
ISSN:1755-1307
1755-1315
DOI:10.1088/1755-1315/459/6/062094