Calibration of a superconducting gravimeter with an absolute atom gravimeter
We present a 27-day-long common view measurement of an absolute cold atom gravimeter (CAG) and a relative iGrav superconducting gravimeter, which we use to calibrate the iGrav scale factor. This allowed us to push the CAG long-term stability down to the level of 0.5 nm s - 2 . We investigate the imp...
Gespeichert in:
Veröffentlicht in: | J.Geod 2021-05, Vol.95 (5), Article 62 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We present a 27-day-long common view measurement of an absolute cold atom gravimeter (CAG) and a relative iGrav superconducting gravimeter, which we use to calibrate the iGrav scale factor. This allowed us to push the CAG long-term stability down to the level of 0.5 nm s
-
2
. We investigate the impact of the duration of the measurement on the uncertainty in the determination of the correlation factor and show that it is limited to about 3‰ by the coloured noise of our cold atom gravimeter. A 3-day-long measurement session with an additional FG5X absolute gravimeter allows us to directly compare the calibration results obtained with two different absolute meters. Based on our analysis, we expect that with an improvement of its long-term stability, the CAG will allow to calibrate the iGrav scale factor to better than the per mille level (1
σ
level of confidence) after only 1 day of concurrent measurements for maximum tidal amplitudes. |
---|---|
ISSN: | 0949-7714 1432-1394 |
DOI: | 10.1007/s00190-021-01516-6 |