Electrochemical sensor based on GCE modified with E-rGO/Poly (B-CD)/magnetic ZIF-67 nanocomposite for the measurement of Linagliptin

Linagliptin (LNG) is one of the drugs that was entered the market in 2011 to treat type 2 diabetes. The drug inhibits the dipeptidyl peptidase-4 enzyme in human body and regulates the insulin level which decreases blood sugar in diabetics. In this work, firstly, GO and magnetic ZIF-67 were synthesiz...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Diamond and related materials 2021-04, Vol.114, p.108345, Article 108345
Hauptverfasser: Baezzat, Mohammad Reza, Shojaei, Fatemeh
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Linagliptin (LNG) is one of the drugs that was entered the market in 2011 to treat type 2 diabetes. The drug inhibits the dipeptidyl peptidase-4 enzyme in human body and regulates the insulin level which decreases blood sugar in diabetics. In this work, firstly, GO and magnetic ZIF-67 were synthesized. The modification of the glassy carbon electrode (GCE) was performed layered by layer. GO was reduced on the electrode surface by the electrochemical method (E-rGO). Then β-cyclodextrin was electrodeposited (Poly (β-CD)) on the E-rGO. Finally, Fe3O4@ZIF-67 (magnetic ZIF-67) nanocomposite was cast on the E-rGO-Poly (β-CD) and was let dry at room temperature completely and was used as a very sensitive sensor to measure the LNG. The performance of the prepared electrodes was evaluated using cyclic voltammetry, electrochemical impedance, spectroscopy, and field emission scanning electron microscopy methods. The results showed that the oxidation current of LNG on the surface of the modified electrodes at a potential of 1.0 V is much higher than that of the GCE. The high surface area of GCE/E-rGO/Poly (B-CD)/magneticZIF-67 showed that the effective synergistic effect of rGO, B-CD, and magneticZIF-67 for the oxidation of LNG, so that the current at the surface of GCE/E-rGO/Poly (B-CD)/magnetic ZIF-67 was 4 times that of the unmodified electrode. Applicability of the sensor was monitored in various concentrations of LNG under linear ranges of 0.03–200 μM and a limit of detection of 0.01 μM was resulted. Also, the sensor showed a good ability to measure LNG in the presence of other species. [Display omitted] •Modified electrode involve E-rGO/Poly (B-CD)/magnetic ZIF-67 nanocomposite were used.•A sensitive method was developed for LNG detection.•Wide linear dynamic range (0.03–200 μM) and LOD of 0.01 μM were obtained.•The suggested method was successfully applied for LNG detection in real sample.
ISSN:0925-9635
1879-0062
DOI:10.1016/j.diamond.2021.108345