Development of the CMC for air kerma Ka for x-ray reference beams in the RQR-M qualities of the IEC 61267:2005 at the SSDL-ININ
The SSDL-ININ developed the Calibration Measurement Capabilities (CMC) for air kerma (Ka) for X-ray reference beams in the IEC 61267:2005 RQR-M qualities for mammography. In this work the following parameters were determined: namely, the practical peak voltage (PPV) and the first half-value layer (H...
Gespeichert in:
Veröffentlicht in: | AIP conference proceedings 2021-04, Vol.2348 (1) |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | 1 |
container_start_page | |
container_title | AIP conference proceedings |
container_volume | 2348 |
creator | Vertti, Mario Raymundo Cabrera Rodríguez, María de los Ángeles Montes Romero, José Trinidad Álvarez |
description | The SSDL-ININ developed the Calibration Measurement Capabilities (CMC) for air kerma (Ka) for X-ray reference beams in the IEC 61267:2005 RQR-M qualities for mammography. In this work the following parameters were determined: namely, the practical peak voltage (PPV) and the first half-value layer (HVL1). Additionally, Monte Carlo (MC) simulations are done to calculate their mean energies (E¯), and to verify that these parameters’ values are within the tolerances indicated by the IEC 61267:2005. |
doi_str_mv | 10.1063/5.0051643 |
format | Article |
fullrecord | <record><control><sourceid>proquest_scita</sourceid><recordid>TN_cdi_proquest_journals_2520004123</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2520004123</sourcerecordid><originalsourceid>FETCH-LOGICAL-p1333-4393f4506eb9baeb8c148b1d05404bf2b31d1fb7f0bbb0e94bbe7ada1b95378c3</originalsourceid><addsrcrecordid>eNp9kUtLAzEUhYMoWKsL_0HAnZCaTJJ5uJOx6mBbsVVwF5KZG5zaeTQzLXblX3dsK-5cXTh859zDvQidMzpg1OdXckCpZL7gB6jHpGQk8Jl_iHqURoJ4gr8do5OmmVPqRUEQ9tDXLaxhUdUFlC2uLG7fAcfjGNvKYZ07_AGu0PhRb4VP4vQGO7DgoEwBG9BFg_Ny65o-T8kYL1d6kbc5NL9hyTDGPvP84NrrmmHdbtXZ7HZEkkkyOUVHVi8aONvPPnq9G77ED2T0dJ_ENyNSM845ETziVkjqg4mMBhOmTISGZVQKKoz1DGcZsyaw1BhDIRLGQKAzzUwkeRCmvI8udrm1q5YraFo1r1au7FYqT3bNqGAe76jLHdWkeavbvCpV7fJCu41aV05JtT-uqjP7H8yo-vnGn4F_Axard_4</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2520004123</pqid></control><display><type>article</type><title>Development of the CMC for air kerma Ka for x-ray reference beams in the RQR-M qualities of the IEC 61267:2005 at the SSDL-ININ</title><source>AIP Journals Complete</source><creator>Vertti, Mario Raymundo Cabrera ; Rodríguez, María de los Ángeles Montes ; Romero, José Trinidad Álvarez</creator><contributor>Porras-Chaverri, Mariela Adelaida ; Rosado-Mendez, Ivan Miguel ; Galavis, Paulina Esther ; Morales-Barcenas, Jose Hector ; Hernández-Bojórquez, Mariana</contributor><creatorcontrib>Vertti, Mario Raymundo Cabrera ; Rodríguez, María de los Ángeles Montes ; Romero, José Trinidad Álvarez ; Porras-Chaverri, Mariela Adelaida ; Rosado-Mendez, Ivan Miguel ; Galavis, Paulina Esther ; Morales-Barcenas, Jose Hector ; Hernández-Bojórquez, Mariana</creatorcontrib><description>The SSDL-ININ developed the Calibration Measurement Capabilities (CMC) for air kerma (Ka) for X-ray reference beams in the IEC 61267:2005 RQR-M qualities for mammography. In this work the following parameters were determined: namely, the practical peak voltage (PPV) and the first half-value layer (HVL1). Additionally, Monte Carlo (MC) simulations are done to calculate their mean energies (E¯), and to verify that these parameters’ values are within the tolerances indicated by the IEC 61267:2005.</description><identifier>ISSN: 0094-243X</identifier><identifier>EISSN: 1551-7616</identifier><identifier>DOI: 10.1063/5.0051643</identifier><identifier>CODEN: APCPCS</identifier><language>eng</language><publisher>Melville: American Institute of Physics</publisher><subject>High density storage ; Parameters ; Tolerances</subject><ispartof>AIP conference proceedings, 2021-04, Vol.2348 (1)</ispartof><rights>Author(s)</rights><rights>2021 Author(s). Published by AIP Publishing.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/acp/article-lookup/doi/10.1063/5.0051643$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,776,780,785,786,790,4498,23909,23910,25118,27901,27902,76353</link.rule.ids></links><search><contributor>Porras-Chaverri, Mariela Adelaida</contributor><contributor>Rosado-Mendez, Ivan Miguel</contributor><contributor>Galavis, Paulina Esther</contributor><contributor>Morales-Barcenas, Jose Hector</contributor><contributor>Hernández-Bojórquez, Mariana</contributor><creatorcontrib>Vertti, Mario Raymundo Cabrera</creatorcontrib><creatorcontrib>Rodríguez, María de los Ángeles Montes</creatorcontrib><creatorcontrib>Romero, José Trinidad Álvarez</creatorcontrib><title>Development of the CMC for air kerma Ka for x-ray reference beams in the RQR-M qualities of the IEC 61267:2005 at the SSDL-ININ</title><title>AIP conference proceedings</title><description>The SSDL-ININ developed the Calibration Measurement Capabilities (CMC) for air kerma (Ka) for X-ray reference beams in the IEC 61267:2005 RQR-M qualities for mammography. In this work the following parameters were determined: namely, the practical peak voltage (PPV) and the first half-value layer (HVL1). Additionally, Monte Carlo (MC) simulations are done to calculate their mean energies (E¯), and to verify that these parameters’ values are within the tolerances indicated by the IEC 61267:2005.</description><subject>High density storage</subject><subject>Parameters</subject><subject>Tolerances</subject><issn>0094-243X</issn><issn>1551-7616</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp9kUtLAzEUhYMoWKsL_0HAnZCaTJJ5uJOx6mBbsVVwF5KZG5zaeTQzLXblX3dsK-5cXTh859zDvQidMzpg1OdXckCpZL7gB6jHpGQk8Jl_iHqURoJ4gr8do5OmmVPqRUEQ9tDXLaxhUdUFlC2uLG7fAcfjGNvKYZ07_AGu0PhRb4VP4vQGO7DgoEwBG9BFg_Ny65o-T8kYL1d6kbc5NL9hyTDGPvP84NrrmmHdbtXZ7HZEkkkyOUVHVi8aONvPPnq9G77ED2T0dJ_ENyNSM845ETziVkjqg4mMBhOmTISGZVQKKoz1DGcZsyaw1BhDIRLGQKAzzUwkeRCmvI8udrm1q5YraFo1r1au7FYqT3bNqGAe76jLHdWkeavbvCpV7fJCu41aV05JtT-uqjP7H8yo-vnGn4F_Axard_4</recordid><startdate>20210430</startdate><enddate>20210430</enddate><creator>Vertti, Mario Raymundo Cabrera</creator><creator>Rodríguez, María de los Ángeles Montes</creator><creator>Romero, José Trinidad Álvarez</creator><general>American Institute of Physics</general><scope>8FD</scope><scope>H8D</scope><scope>L7M</scope></search><sort><creationdate>20210430</creationdate><title>Development of the CMC for air kerma Ka for x-ray reference beams in the RQR-M qualities of the IEC 61267:2005 at the SSDL-ININ</title><author>Vertti, Mario Raymundo Cabrera ; Rodríguez, María de los Ángeles Montes ; Romero, José Trinidad Álvarez</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-p1333-4393f4506eb9baeb8c148b1d05404bf2b31d1fb7f0bbb0e94bbe7ada1b95378c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>High density storage</topic><topic>Parameters</topic><topic>Tolerances</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vertti, Mario Raymundo Cabrera</creatorcontrib><creatorcontrib>Rodríguez, María de los Ángeles Montes</creatorcontrib><creatorcontrib>Romero, José Trinidad Álvarez</creatorcontrib><collection>Technology Research Database</collection><collection>Aerospace Database</collection><collection>Advanced Technologies Database with Aerospace</collection><jtitle>AIP conference proceedings</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vertti, Mario Raymundo Cabrera</au><au>Rodríguez, María de los Ángeles Montes</au><au>Romero, José Trinidad Álvarez</au><au>Porras-Chaverri, Mariela Adelaida</au><au>Rosado-Mendez, Ivan Miguel</au><au>Galavis, Paulina Esther</au><au>Morales-Barcenas, Jose Hector</au><au>Hernández-Bojórquez, Mariana</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of the CMC for air kerma Ka for x-ray reference beams in the RQR-M qualities of the IEC 61267:2005 at the SSDL-ININ</atitle><jtitle>AIP conference proceedings</jtitle><date>2021-04-30</date><risdate>2021</risdate><volume>2348</volume><issue>1</issue><issn>0094-243X</issn><eissn>1551-7616</eissn><coden>APCPCS</coden><abstract>The SSDL-ININ developed the Calibration Measurement Capabilities (CMC) for air kerma (Ka) for X-ray reference beams in the IEC 61267:2005 RQR-M qualities for mammography. In this work the following parameters were determined: namely, the practical peak voltage (PPV) and the first half-value layer (HVL1). Additionally, Monte Carlo (MC) simulations are done to calculate their mean energies (E¯), and to verify that these parameters’ values are within the tolerances indicated by the IEC 61267:2005.</abstract><cop>Melville</cop><pub>American Institute of Physics</pub><doi>10.1063/5.0051643</doi><tpages>3</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0094-243X |
ispartof | AIP conference proceedings, 2021-04, Vol.2348 (1) |
issn | 0094-243X 1551-7616 |
language | eng |
recordid | cdi_proquest_journals_2520004123 |
source | AIP Journals Complete |
subjects | High density storage Parameters Tolerances |
title | Development of the CMC for air kerma Ka for x-ray reference beams in the RQR-M qualities of the IEC 61267:2005 at the SSDL-ININ |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-14T06%3A20%3A03IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_scita&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20the%20CMC%20for%20air%20kerma%20Ka%20for%20x-ray%20reference%20beams%20in%20the%20RQR-M%20qualities%20of%20the%20IEC%2061267:2005%20at%20the%20SSDL-ININ&rft.jtitle=AIP%20conference%20proceedings&rft.au=Vertti,%20Mario%20Raymundo%20Cabrera&rft.date=2021-04-30&rft.volume=2348&rft.issue=1&rft.issn=0094-243X&rft.eissn=1551-7616&rft.coden=APCPCS&rft_id=info:doi/10.1063/5.0051643&rft_dat=%3Cproquest_scita%3E2520004123%3C/proquest_scita%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2520004123&rft_id=info:pmid/&rfr_iscdi=true |