Effect of Fins spacing on the Performance Evaluation of a Refrigeration System using LPG as Refrigerant

In this paper, experimental analysis was carried out on a vapour compression system by varying the parallel tube condenser fins spacing under the same atmospheric condition in a selected Refrigeration and Air-conditioning laboratory to examine the performance characteristics of the refrigeration sys...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:IOP conference series. Earth and environmental science 2021-03, Vol.665 (1), p.12030
Hauptverfasser: Banjo, S.O., Fayomi, O.S.I., Atayero, A.A.A., Bolaji, B.O., Dirisu, J.O., Okeniyi, J., Emetere, M.E., Olorunfemi, B. J, Owoeye, T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, experimental analysis was carried out on a vapour compression system by varying the parallel tube condenser fins spacing under the same atmospheric condition in a selected Refrigeration and Air-conditioning laboratory to examine the performance characteristics of the refrigeration system. The fins spacing were 2, 4 and 6 mm using Liquefied petroleum gas (LPG) as working fluid with a mixture proportion of 17.2% isobutene, 56.4% butane, 24.4% propane. The result shows that the coefficient of performance of the system when working with condenser fins spacing of 2 mm was 28.8 and 35.9% higher compared to when the system worked with the fins spacing of 4 and 6 mm respectively. Energy consumed by the single hermetic compressor when the system worked with condenser fins spacing of 2 mm reduced by 16.4 and 18.7% compared to when the refrigerator worked with fins spacing of 4 and 6 mm respectively. The pull down time of the cooling system was attained in 2 hours 45 minute with minimum evaporator temperature of -13 °C while working with 30 g mass charge of LPG.
ISSN:1755-1307