0530 ARE WE UNDERSELLING POSITIVE AIRWAY PRESSURE (PAP) COMPLIANCE AND CONFOUNDING SLEEP RESEARCH? LARGE MULTI-CENTER ANALYSIS SHOWS PAP COMPLIANCE DATA THAT IS MUCH HIGHER THAN PREVIOUSLY REPORTED

Abstract Introduction: Clinical sleep medicine is guided by published literature that drive treatment. For obstructive sleep apnea (OSA), many such studies are flawed because treatment groups used for analysis have Positive Airway Pressure (PAP) compliance levels lower even than current minimum Medi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sleep (New York, N.Y.) N.Y.), 2017-04, Vol.40 (suppl_1), p.A197-A198
Hauptverfasser: Meskill, GJ, Simmons, JH, Hua, O, Legan, A, Weiss, T, Bastida, A, Peters, BR
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Abstract Introduction: Clinical sleep medicine is guided by published literature that drive treatment. For obstructive sleep apnea (OSA), many such studies are flawed because treatment groups used for analysis have Positive Airway Pressure (PAP) compliance levels lower even than current minimum Medicare requirements for ongoing treatment coverage. Acceptance of poor PAP usage data stems from previous publications on PAP compliance, which have similar flaws and small cohorts (i.e., < 100 subjects). We contend that such studies cite compliance thresholds that easily are eclipsed by sleep centers employing effective protocols, and utilization of these data lead to conclusions hindering proper progression of sleep medicine. We collected data to demonstrate higher PAP compliance can be achieved than what currently is reported. Methods: We analyzed 1580 consecutive patient charts from two comprehensive sleep centers, Comprehensive Sleep Medicine Associates (Greater Houston, TX) and Pulmonary and Sleep Associates of Marin (Novato, CA). Included were patients who had received a PAP device for OSA 90+ days prior to data analysis and whose compliance could be tracked remotely through AirView. All others were excluded. Compliance was defined in two ways: “CMS compliance” (4+ hours of PAP use for 21/30 consecutive days within the first 90 days of PAP initiation) and “all compliance” (4+ hours of PAP use for 21/30 consecutive days within any 90-day period). Results: 1383 patients met inclusion criteria. 964 (70%) met CMS compliance, and 1072 (78%) met all compliance. 26% (110 patients) of those who did not meet CMS compliance later became compliant. Conclusion: Our results show higher PAP compliance than prior studies. Examples of flawed studies utilizing sub-optimal PAP compliance include, “Noninferiority of Functional Outcome in Ambulatory Management of Obstructive Sleep” (Kuna, 2011) and “Lack of Secondary Cardiovascular Morbidity Prevention with PAP” (McEvoy, 2016). Both used PAP treatment groups with average compliance far below the CMS compliance threshold. Higher compliance levels similar to ours are not unreasonable to obtain, but may require comprehensive measures, including aggressive clinical follow-up, concomitant cognitive behavioral therapy for insomnia, collaboration with other health professionals, clinic interventions (e.g., mask fittings, PAP Naps), and proper pressure settings. Support (If Any): N/A.
ISSN:0161-8105
1550-9109
DOI:10.1093/sleepj/zsx050.529