Louver and effusion cooling heat transfer for a double wall effusion plate with impingement jet array coolant supply
•Louver slot cooling is employed so that cooling air advects as a protective layer downstream along the test surface.•Line-averaged adiabatic effectiveness results show that louver and effusion cooling arrangement often provides higher effectiveness, relative to an effusion cooling only arrangement....
Gespeichert in:
Veröffentlicht in: | International journal of heat and mass transfer 2021-04, Vol.168, p.120861, Article 120861 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •Louver slot cooling is employed so that cooling air advects as a protective layer downstream along the test surface.•Line-averaged adiabatic effectiveness results show that louver and effusion cooling arrangement often provides higher effectiveness, relative to an effusion cooling only arrangement.•An advantage of the louver slot is more uniform values of increased effectiveness along the entire test surface, including locations which are just downstream of the slot.•Relatively weak dependence on blowing ratio is present for the louver and film cooling arrangement, in contrast to the effusion only configuration.•For blowing ratios of 5.2 to 5.5, louver and effusion cooling gives lower line-averaged heat transfer coefficients (relative to effusion cooling only) because of reduced local turbulent thermal transport levels within wakes downstream of louver leap device.
Louver slot cooling is employed, which consists of an aligned collection of film cooling holes, contained within a specially-designed device which concentrates, and directs the coolant from a slot, so that cooling air then advects as a layer downstream along the test surface. This louver-supplied coolant is then supplemented by coolant which emerges from different rows of downstream film cooling holes. Coolant for both cooling arrangements is supplied using an array of impingement jets. Experimental data are provided for a mainstream Reynolds number Rems range of 168,000–181,000. Full-coverage film cooling initial blowing ratio values are 2.5, 3.2, 4.4, and 5.2, with respective louver slot blowing ratios of 1.2, 1.5, 2.1, and 2.4. Measured lateral-averaged adiabatic effectiveness results show that, with impingement supply cooling only, for blowing ratios of 4.4 and lower, the louver and effusion cooling arrangement generally provides higher effectiveness, relative to an effusion cooling only arrangement. For all blowing ratios considered, another advantage of the louver slot is more uniform values of increased effectiveness along the entire test surface, including locations which are just downstream of the slot. Relatively weak dependence on blowing ratio is present for the louver and film cooling arrangement, in contrast to the effusion only configuration, where effectiveness data generally increase progressively and substantially (at most x/de locations) as the blowing ratio becomes larger. Lateral-averaged heat transfer coefficient values for the effusion cooling only arrangement, and for th |
---|---|
ISSN: | 0017-9310 1879-2189 |