Enhanced heat transfer performance for multi-tube heat exchangers with various tube arrangements

•A numerical evaluation of multi-tube heat exchangers was conducted.•The enhanced heat transfer mechanism was entropy analyzed.•The heat transfer performance was opposite to the spiral flow intensity.•The performance of staggered is better than the identical tube arrangement. Numerical evaluations w...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of heat and mass transfer 2021-04, Vol.168, p.120905, Article 120905
Hauptverfasser: Wang, Wei, Shuai, Yong, Li, Bingrui, Li, Bingxi, Lee, Kwan-Soo
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•A numerical evaluation of multi-tube heat exchangers was conducted.•The enhanced heat transfer mechanism was entropy analyzed.•The heat transfer performance was opposite to the spiral flow intensity.•The performance of staggered is better than the identical tube arrangement. Numerical evaluations were conducted on multi-tube heat exchangers with transverse corrugated tubes and helically corrugated tubes. The complex flow features (coupled by multiple secondary flow, spiral flow and turbulent pulsation) and enhanced heat transfer mechanism were analyzed by coupling the global flow contours and entropy generation distributions. The average performances were measured using two evaluation methods. The results showed that the produced spiral flows have little effect on thermal efficiency, but can inhibit the increment of flow resistance significantly. The two evaluation methods for the four cases presented the same results, that the multi-tube heat exchanger with staggered tube arrangement of helically corrugated tube show the best overall performance than the other cases. The thermal efficiency can improve 2.46~1.61 and the pumping power increases 5.86~5.25 compared with the multi-tube heat exchanger with smooth tubes, under the Reynolds number 7, 200~36, 000. In order to ensure the energy benefit is positive the Reynolds number should be maintained above 25, 200 to keep performance evaluation criterion above 1.0 and Bejan number could above 0.85, simultaneously. In addition, the identical tube arrangement of helically corrugated tube is the optimum case, according to the two-objective optimization with heat flux and pumping power.
ISSN:0017-9310
1879-2189
DOI:10.1016/j.ijheatmasstransfer.2021.120905