Performance assessment of PVT-air collector with V-groove absorber: A theoretical and experimental analysis

In this paper, the performance of a PVT (photovoltaic thermal) air collector with V-groove absorber in the air channel is theoretically and experimentally examined under different climate conditions of Ghaziabad city, India, in summer, June 2019. A low power brushless DC fan is fixed at the input of...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Heat and mass transfer 2021-04, Vol.57 (4), p.665-679
Hauptverfasser: Diwania, Sourav, Siddiqui, Anwar S., Agrawal, Sanjay, Kumar, Rajeev
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this paper, the performance of a PVT (photovoltaic thermal) air collector with V-groove absorber in the air channel is theoretically and experimentally examined under different climate conditions of Ghaziabad city, India, in summer, June 2019. A low power brushless DC fan is fixed at the input of the air-channel to ensure the circulation of air through the V-groove. The energy balance equation is developed with the matrix-inversion method to estimate the PV (photovoltaic) cell and air output temperatures. The theoretical results obtained using mathematical modeling has been compared with that of the real-time experimental results. The electrical, thermal, and overall efficiencies for the theoretical and experimental studies are found in the range of 10.39–10.26%, 41.78–41.57%, and 52.17–51.81%, respectively. It has been observed that the theoretical results are coherent with experimental results for the proposed model achieving an accuracy of 98.98%, 99.43%, and 99.31% for electrical, thermal, and overall efficiencies, respectively.
ISSN:0947-7411
1432-1181
DOI:10.1007/s00231-020-02980-0