[Technical Note] The Effect of Variables on Laboratory Termite Testing: Part II—Effect of Grain Orientation of Test Blocks
The effect of test-block grain orientation on laboratory termite tests using American Wood-Preservers' Association Standard E1-97 was evaluated using Coptotermes formosanus . This research revealed that testing of samples with the 6-mm direction in either the longitudinal or the tangential dire...
Gespeichert in:
Veröffentlicht in: | Forest products journal 2020-01, Vol.70 (4), p.459-461 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The effect of test-block grain orientation on laboratory termite tests using American Wood-Preservers' Association Standard E1-97 was evaluated using Coptotermes formosanus . This research revealed that testing of samples with the 6-mm direction in either the longitudinal or the tangential direction was appropriate. The E1 standard was subsequently modified to allow either. |
---|---|
ISSN: | 0015-7473 2376-9637 |
DOI: | 10.13073/FPJ-D-20-00044 |