A Study of High Transient Voltage Unit Realization Uncertainty

The problem of the metrological provision of generators of high-voltage voltage pulses with subnanosecond front rise time has been solved, as well as pulsed voltage splitters used in power engineering, aviation, and aerospace industries. As a result of the completion of the State Primary Special Sta...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Measurement techniques 2021, Vol.63 (10), p.823-827
Hauptverfasser: Sukhov, A. V., Sakharov, K. Yu, Zolotarevsky, Yu. M., Mikheev, O. V., Turkin, V. A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The problem of the metrological provision of generators of high-voltage voltage pulses with subnanosecond front rise time has been solved, as well as pulsed voltage splitters used in power engineering, aviation, and aerospace industries. As a result of the completion of the State Primary Special Standard for units of the intensities of pulsed electrical and magnetic fields with pulse front rise times in the range 0.1–10.0 ns per GET 148-2013, a mode of implementing the reproduction of the unit of high transient electric voltage with a minimum pulse front rise time of 100 ps has been implemented. The uncertainties of reconstituting the unit of high transient electric voltage, obtained by numerical modeling with the Monte Carlo method, are evaluated, as well as in accordance with the Guide to the Expression of Uncertainty in Measurement (GUM). Likewise, the error of reproduction of the unit according to GOST 8.381-2009, “GSI. Standards. Methods of Expression of Precision,” is evaluated.
ISSN:0543-1972
1573-8906
DOI:10.1007/s11018-021-01859-8