A method based on GA-LSSVM for COP prediction and load regulation in the water chiller system

[Display omitted] •A method based on GA-LSSVM has been used for performance prediction and load regulation.•Two systems applied in different situations have been studied to show the generalizability of the proposed method.•The determination coefficients of two cases are 0.9835 and 0.9907 respectivel...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Energy and buildings 2021-01, Vol.230, p.110604, Article 110604
Hauptverfasser: Pan, Xi, Xing, Ziwen, Tian, Chengcheng, Wang, Haojie, Liu, Huaican
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:[Display omitted] •A method based on GA-LSSVM has been used for performance prediction and load regulation.•Two systems applied in different situations have been studied to show the generalizability of the proposed method.•The determination coefficients of two cases are 0.9835 and 0.9907 respectively.•A control strategy has been presented in detailed based on the proposed model. In this paper, a method based on least square support vector machine (LSSVM) and genetic algorithm (GA) is applied for the coefficient of performance (COP) prediction and the load regulation of each chiller in the water chiller system. In order to show the generalizability of this method, two twin-screw water chiller systems with different nominal cooling capacities applied in different situations are studied. The proposed model uses two compressors’ load rate, inlet temperature of cooling water, outlet temperature of cooling water, inlet temperature of condensing water and outlet temperature of condensing water as input parameters. COP is used as the output parameter. To increase the accuracy of the model, more than 10,000 on-site testing data points are randomly divided into the training set and the testing set for each case. The results show that this GA-LSSVM-based model is accurate enough for COP prediction. For the first case, 98.05% of total points locate within the ± 5% lines and determination coefficient is 0.9835. For the second case, 99.66% of total points locate within the ± 5% lines and determination coefficient is 0.9907. Based on the proposed model with high precision, two different typical working conditions are used for two cases to develop the control strategy of each chiller’s load regulation, which is significantly helpful to improve the performance of the water chiller system.
ISSN:0378-7788
1872-6178