Lipid microsphere bound oxycodone for pain management in patients receiving radiotherapy for head and neck cancer
Background Wax microsphere bound oxycodone was developed as an abuse-deterrent opioid and maintains a similar pharmacokinetic profile whether administered with or without an intact capsule. We hypothesized that microsphere oxycodone could be utilized for extended release analgesia in patients underg...
Gespeichert in:
Veröffentlicht in: | Supportive care in cancer 2021, Vol.29 (1), p.263-269 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background
Wax microsphere bound oxycodone was developed as an abuse-deterrent opioid and maintains a similar pharmacokinetic profile whether administered with or without an intact capsule. We hypothesized that microsphere oxycodone could be utilized for extended release analgesia in patients undergoing radiation (RT) for head-and-neck cancer (HNC) and would not need to be discontinued due to dysphagia or gastrostomy tube dependence.
Methods and materials
We performed a prospective trial that enrolled participants > 18 years with histologically confirmed HNC who were scheduled to receive RT. Analgesia was prescribed in accordance with the WHO pain ladder. Microsphere oxycodone was initiated when total daily opioid dose exceeded 30 mg of morphine sulfate equivalent and was titrated weekly during RT. Pain level and effect on quality of life were assessed using the Brief Pain Inventory. The primary feasibility endpoint was frequency of microsphere oxycodone discontinuation within 3 months of RT for reasons other than pain resolution.
Results
Twenty-six eligible patients were enrolled. Microsphere oxycodone was initiated in 16 (61.5%) patients. Six (23.1%) patients utilized a gastrostomy tube to administer microsphere oxycodone during all or part of RT. Microsphere oxycodone was discontinued in 1 (7.6%) patient due to perceived inefficacy. No patients were discontinued due to toxicity or difficulty with administration. Ratings for average pain was 3.1 (± 3.4) at enrollment, 4.0 (± 2.4) at week 6 of RT, and 1.8 (± 2.2) at 3-month follow-up.
Conclusions
These results support the feasibility and safety of microsphere oxycodone for extended release analgesia among patients with HNC undergoing RT. |
---|---|
ISSN: | 0941-4355 1433-7339 |