Removal of Poly- and Per-Fluorinated Compounds from Ion Exchange Regenerant Still Bottom Samples in a Plasma Reactor

“High-concentration” and “low-concentration” bench-scale batch plasma reactors were used to effectively degrade per- and polyfluoroalkyl substances (PFAS) at a high concentration (∼100 mg/L) and a low concentration (99.9% in 2 h, and short-chain PFAAs (99% of the TOP present in SBs was removed durin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Environmental science & technology 2020-11, Vol.54 (21), p.13973-13980
Hauptverfasser: Singh, Raj Kamal, Multari, Nicholas, Nau-Hix, Chase, Woodard, Steven, Nickelsen, Michael, Mededovic Thagard, Selma, Holsen, Thomas M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:“High-concentration” and “low-concentration” bench-scale batch plasma reactors were used to effectively degrade per- and polyfluoroalkyl substances (PFAS) at a high concentration (∼100 mg/L) and a low concentration (99.9% in 2 h, and short-chain PFAAs (99% of the TOP present in SBs was removed during the treatment. Fluorine recovery of 47 to 117% was obtained in six SB samples. Energy requirement (EE/O) for the treatment of PFOA and PFOS from SBs ranged from 380 to 830 kWh/m3.