Electrochemical platform for the detection of adenosine using a sandwich-structured molecularly imprinted polymer-based sensor

An innovative sandwich MIP-based electrochemical sensor was fabricated for the fast and selective detection of adenosine. The covalent-imprinted biomimetic recognition element relies on two overlapping polymeric films, an underlaying composite boronate-affinity and poly(bithiophene)-structural layer...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrochimica acta 2020-09, Vol.354, p.136656, Article 136656
Hauptverfasser: Gliga, Laura-Elena, Iacob, Bogdan-Cezar, Cheșcheș, Bianca, Florea, Adrian, Barbu-Tudoran, Lucian, Bodoki, Ede, Oprean, Radu
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:An innovative sandwich MIP-based electrochemical sensor was fabricated for the fast and selective detection of adenosine. The covalent-imprinted biomimetic recognition element relies on two overlapping polymeric films, an underlaying composite boronate-affinity and poly(bithiophene)-structural layer and an overlaying poly(3-indolacetic acid) coating bearing carboxyl groups, intended to further shape the selectivity of the sensor towards adenosine. The sensor’s behavior and analytical performance was characterized by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS). The recorded DPVs showed a linear response to increasing concentration of adenosine in the range of 0.37 μM–37.4 μM with a limit of detection of 0.21 μM. The selectivity of the MIP sensor towards adenosine was demonstrated against more than 10 structurally related interferents. The developed sensor was applied for the fast and quantitative assessment of adenosine in spiked urine samples with good recoveries (102.98%–106.34%), proving at least comparable bioanalytical performances in terms of sensitivity, yet greatly improved in terms of selectivity and analysis time to previously reported sensors. •First study reporting MIP-based electrochemical sensor for adenosine determination.•Biomimetic sandwich-structured sensing interface for the detection of adenosine.•Dual imprinting process by spatially-oriented covalent and non-covalent interactions.•Facile manufacturing of multi-use electrochemical sensor offering short analysis times.•Very good selectivity demonstrated on many analytically relevant interferents.
ISSN:0013-4686
1873-3859
DOI:10.1016/j.electacta.2020.136656