Determination of parameters affecting the accuracy of GNSS station velocities
•The parameters affecting GNSS station velocities were investigated.•A new mathematical model has been developed with multiple regression analysis.•The time between campaigns effects station velocity accuracy.•Effect of a lot campaigns on accuracy is limited. In this study, the main factors affectin...
Gespeichert in:
Veröffentlicht in: | Measurement : journal of the International Measurement Confederation 2020-11, Vol.164, p.108003, Article 108003 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | •The parameters affecting GNSS station velocities were investigated.•A new mathematical model has been developed with multiple regression analysis.•The time between campaigns effects station velocity accuracy.•Effect of a lot campaigns on accuracy is limited.
In this study, the main factors affecting the velocities of Global Navigation Satellite System (GNSS) stations were investigated. In order to improve the accuracy of GNSS station velocities, the optimal number of campaigns, the total time period between the individual campaigns, and session observation time were investigated using 14 campaigns of GNSS data obtained from eight Continuously Operating Reference Stations (CORS-TR). In addition, multiple regression analysis was performed to statistically test the effect of the determined parameters. The determined regression parameters enable to estimate the accuracy of GNSS station velocity that could be obtained when the number of campaigns, observation time and the total time period between the first and the last campaign are given. As a result, it was determined that the relationship between the accuracy of GNSS station velocity values and the time between the campaigns was t(observation time), and the inverse ratio was approximately two times. |
---|---|
ISSN: | 0263-2241 1873-412X |
DOI: | 10.1016/j.measurement.2020.108003 |