Composite behavior in RC buildings retrofitted using buckling-restrained braces with elastic steel frames

•Investigation of composite behavior in RC buildings retrofitted using BRBs with steel frame (SF).•Proposed retrofit method can avoid damage concentration and secure self-centering function.•Development of a detailed numerical model to simulate the composite behavior between RC and SF.•Development o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Engineering structures 2020-09, Vol.219, p.110896, Article 110896
Hauptverfasser: Saingam, Panumas, Sutcu, Fatih, Terazawa, Yuki, Fujishita, Kazuhiro, Lin, Pao-Chun, Celik, Oguz C., Takeuchi, Toru
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:•Investigation of composite behavior in RC buildings retrofitted using BRBs with steel frame (SF).•Proposed retrofit method can avoid damage concentration and secure self-centering function.•Development of a detailed numerical model to simulate the composite behavior between RC and SF.•Development of a simple design method without iteration incorporating the composite behavior.•Application of the proposed retrofit method to an existing RC school building. Seismically retrofitting reinforced concrete (RC) building with a combination of buckling-restrained braces (BRBs) and elastic steel frames offers a practical solution that provides additional lateral stiffness and energy dissipation capacity. However, the available methods to vertically distribute the BRB sizes based on equivalent linearization do not consider the additional stiffness due to the composite behavior between the RC frame and the elastic steel frame, which may lead to an overly conservative estimate of the BRB stiffness demands. This study proposes a retrofit design method incorporating the composite behavior. Numerical models considering the detailed composite behavior are developed and calibrated against quasi-static cyclic loading tests, and a simplified evaluation method is proposed. A four-story RC school building is used as a benchmark model, and the proposed retrofit design method is validated using nonlinear response history analysis. The analysis results suggest that taking the composite behavior into account by using the proposed retrofit design method more accurately estimates the lateral stiffness of the retrofitted structure and leads to a more economic retrofit.
ISSN:0141-0296
1873-7323
DOI:10.1016/j.engstruct.2020.110896