Performance Analysis of Two-Stage Solid Desiccant Densely Coated Heat Exchangers

In this study, silica gel and sodium polyacrylate desiccants are coated onto a finned tube heat exchanger (Desiccant Coating Heat Exchanger, DCHE), which can absorb the vapor in the process air for dehumidification. In the experiments, the desiccant is coated on fins using the dense coating method,...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Sustainability 2020-09, Vol.12 (18), p.7357
Hauptverfasser: Li, Kun-Ying, Luo, Win-Jet, Tsai, Bo-Yi, Kuan, Yean-Der
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, silica gel and sodium polyacrylate desiccants are coated onto a finned tube heat exchanger (Desiccant Coating Heat Exchanger, DCHE), which can absorb the vapor in the process air for dehumidification. In the experiments, the desiccant is coated on fins using the dense coating method, which causes the fixed fin area to be coated with greater amounts of desiccants for a better dehumidification performance. This study discusses the dehumidification performances of a single stage DCHE and two-stage DCHEs in series under different relative humidity conditions of the inlet process air and different regeneration water temperatures. The results show that the thermal coefficient of performance (COPth) of the DCHEs for the two desiccants prepared by the dense coating method is better than that of DCHEs with the general immersing coating method by a factor of 2–2.4. The two-stage DCHEs in series have a lower supply humidity ratio than a single stage DCHE at different inlet humidity levels, and they can be used in the industry when a special low humidity manufacturing process is required. The overall dehumidifying capacities of two-stage series-connected DCHEs at regeneration temperatures of 50 °C and 70 °C are approximately twice as high as those of a single stage DCHE. The COPth value of a single stage or two stages increases with an increase in the inlet humidity of the process air. The COPth values of the sodium polyacrylate single stage and two-stage DCHEs are 1–1.3 times greater than those of the silica gel single stage and two-stage DCHEs at a high inlet air humidity. Finally, the effects of different regeneration water temperatures on the performance of DCHEs are investigated. With an increase in the regeneration water temperature, the COPth value, dehumidifying capacity and regeneration capacity of single stage or two-stage DCHEs increase as well.
ISSN:2071-1050
2071-1050
DOI:10.3390/su12187357